Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Q98.

...

The

...

landfill

...

industry

...

uses

...

a

...

portable

...

meter

...

that

...

uses

...

an

...

IR

...

method

...

to

...

determine

...

methane

...

and

...

carbon

...

dioxide

...

concentrations.

...

Has

...

the

...

EPA

...

determined

...

if

...

these

...

units

...

are

...

acceptable

...

and

...

comply

...

with

...

the

...

accuracy

...

required

...

by

...

the

...

rule?

...

 

A98. Yes, a portable infrared monitor may be used to comply with the requirements of the final rule. If the infrared monitor measures total hydrocarbons, a correction factor must be established. Some infrared monitors operate in such a manner as to detect only methane; these methane-specific analyzer systems do not need to establish or use a correction factor.

Wiki Markup
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}

Panel

Updated on

Page info
modified-date
modified-date
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1 

Expiration: none 

Relevant Subparts:  Subpart HH
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to}

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)