Using Subpart K Calculation Spreadsheets

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migration of unmigrated content due to installation of a new plugin

Anchor
Top
Top

Excerpt Include
TBSAND:Spreadsheet Usage Warning
TBSAND:Spreadsheet Usage Warning
nopaneltrue

Overview

This help page provides guidance for working with the supplemental Subpart K Calculation Spreadsheet. The guidance provides step-by-step instructions for the following tasks:

h3.anchor
Downloading the Calculation Spreadsheet

The calculation spreadsheet for Subpart K may be downloaded by clicking the link in the first column of the table below. Users may also jump to instructions for each calculation spreadsheet by clicking the link in the second column.

Calculation Spreadsheet
(click to download)

Instructions
(click to view)

Equation K-1, K-3 Calculation Spreadsheet.xls

K-1, K-3 Help

h3.anchor
General Information on Using a Calculation Spreadsheet

The guidance provided in this section applies to calculation spreadsheets for all subparts. Additional guidance specific to Subpart K is provided in the following section.

Include Page
TBSAND:Spreadsheet Color Coding
TBSAND:Spreadsheet Color Coding
Include Page
TBSAND:Spreadsheet Stop and Warning Messages
TBSAND:Spreadsheet Stop and Warning Messages

h3.anchor
Using the Equation K-1, K-3 Calculation Spreadsheet

Use the Equation K-1, K-3 Calculation Spreadsheet to calculate the annual CO2 and CH4 process emissions from an electric arc furnace. A separate spreadsheet is to be used for each furnace. Users should not use aggregated data from multiple furnaces in a single calculation spreadsheet. The Equation K-1, K-3 Calculation Spreadsheet performs the calculations using Equations K-1 and K-3, provided below (see calculation spreadsheet for definitions of variables). 

 

(Equation K-1)
(Equation K-3)

 

Begin by entering the facility name, your name, the furnace name or identifier, the reporting period and any additional comments in the green input cells of the General Information table located immediately below the equations in the calculation spreadsheet. This is for your records.

Next, enter the requested information in the green input cells of the input data tables.






The calculation spreadsheet will then calculate the annual CO2 and CH4 process emissions from this electric arc furnace. The calculated values will be displayed in red-bordered cells in the K-1, K-3 Results tables at the bottom of the spreadsheet. This value should be entered in e-GGRT for this furnace.