Q119. Are annubars or v-cone flowmeters acceptable for compliance with the rule requirements?


A119. Annubar and/or v-cone flow meters (and any other type of flow meter) are allowed under the rule provided they meet the accuracy requirements for flow meters in Section 98.3(i). Calibration would be done as specified by the manufacturer if none of the methods listed in Section 98.344(c) are applicable.

Wiki Markup
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}

Panel

Updated on

Page info
modified-date
modified-date
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ, revised by R. Schmeltz, 2/11/2013

Approval / Publishing History: Version 2, approved by L. Grogan-McCulloch, 2/13/2013

Expiration : none

Relevant Subparts: Subpart HH