Q553.
...
For
...
which
...
units
...
of
...
measure
...
are
...
we
...
required
...
to
...
calculate
...
and
...
report
...
emissions
...
using
...
Equation
...
W-3?
...
May
...
we
...
use
...
a
...
flow
...
meter
...
to
...
calculate
...
annual
...
emission
...
CO2?
...
A553. The units of measure for emissions calculated in Equation W-3 are in cubic feet per year. However, §98.233(d)(10) requires that the volumetric emissions of equation W-3 be converted into mass emissions using §98.233(v)’s methods. You must report emissions in metric tons of CO2e to meet the reporting requirements in §98.236(c)(3)(v). If reporters use the methodology set forth in §98.233(d)(2), then a vent flow meter must be used to determine the total annual volume of vent gas flowing out of the AGR unit.
Wiki Markup |
---|
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to} |
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
Updated on
|
Wiki Markup |
---|
{show-to:group=confluence-Users} {info} Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, [http://www.epa.gov/climatechangeghgreporting/documents/emissionspdf/downloads112011/documents/Subpart-W-additional-faq.pdf]. Modified per M. Eaddy 7/26/2012 Approval / Publishing History: Version 2 Expiration : none Relevant Subpart: W, Acid Gas Removal Units {info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to} |