Q769. If a facility does not have a gas-to-oil ratio (GOR) value for a well, what options are available to facilities in order to determine the GOR for associated gas venting and flaring?
{longname}

A769.

...

Facilities

...

have

...

several

...

options

...

to

...

determine

...

GOR

...

for

...

associated

...

gas

...

venting

...

and

...

flaring.

...

If

...

the

...

GOR

...

from

...

each

...

well

...

is

...

not

...

available,

...

EPA

...

has

...

provided

...

flexibility

...

in

...

40

...

CFR

...

98.233(m)

...

and

...

the

...

GOR

...

from

...

a

...

cluster

...

of

...

wells

...

in

...

the

...

same

...

sub-basin

...

category

...

shall

...

be

...

used.

...

If

...

GOR

...

is

...

still

...

not

...

available,

...

then

...

an

...

appropriate

...

standard

...

method

...

published

...

by

...

a

...

consensus-based

...

standards

...

organization

...

or

...

industry

...

standard

...

practice

...

(as

...

described

...

in

...

40

...

CFR

...

98.234(b))

...

may

...

be

...

used.

...

Wiki Markup
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}

{
Panel
}

Updated

on

on

Wiki Markup
{page-info:modified-date|dateformat=dd/MM/YY HH:mm}

\\ {panel}


Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: M. DeFigueiredo, 11/18/2013

Approval / Publishing History: Version 1

Expiration: None

Relevant Subpart: Subpart W BAMM, Onshore Production, Onshore Processing
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to}

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)