{longname} Q100. When does moisture content need to be corrected for in Equation HH-4?

{longname}

A100. If CH4 concentration and flow are both measured on a wet basis or both measured on a dry basis, then no moisture correction is needed. If one is measured on a wet basis and the other on a dry basis, then correction is needed.

\\
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}
{panel}Updated on {page-info:modified-date|dateformat=dd/MM/YY HH:mm}{panel}
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ, revised by R. Schmeltz, 2/11/2013

Approval / Publishing History: Version 1 2, approved by L. Grogan-McCulloch, 2/13/2013

Expiration : none

Relevant Subparts: Subpart HH