Q100. When does moisture content need to be corrected for in Equation HH-4?
A100. If CH4 concentration and flow are both measured on a wet basis or both measured on a dry basis, then no moisture correction is needed. If one is measured on a wet basis and the other on a dry basis, then correction is needed.
Footer / References Bar which is Visible to the public
Updated on
Source: This question and answer was derived from a Legacy FAQ, revised by R. Schmeltz, 2/11/2013
Approval / Publishing History: Version 2, approved by L. Grogan-McCulloch, 2/13/2013
Expiration: none
Relevant Subparts: Subpart HH
History Panel For Internal Use - Not Visible to the Public