Certain validation checks which are considered critical errors must be corrected before you can successfully generate your submission package or upload your XML-based submission. These checks are presented to the reporter when they attempt to generate or regenerate their submission or after they attempt to upload an XML-based submission. These checks are signified with a stop sign in your validation report. The table below provides a list of critical errors. Additional technical information that may assist XML uploaders is also available at XML Upload Critical Errors. If you feel that you have triggered one of these checks in error, or if there’s a reason why your report should be submitted despite the check being triggered, you may submit a request to the e-GGRT Help Desk at GHGReporting@epa.gov.
CODE | SUBPART | TYPE | MESSAGE_TEXT |
---|---|---|---|
CEMSML-1 | N | Data Completeness | Monitoring Location (CML) process units. You have added one or more units monitored by CEMS, but have not yet added a CEMS Monitoring Location (CML). |
CEMSML-2 | N | Data Completeness | CEMS Monitoring Location (CML) process units. You have indicated that this unit is monitored by CEMS, but you have not yet associated it with any CEMS Monitoring Locations (CMLs). From the Subpart Overview page, click on the CML Name/Identifier to which this unit exhausts (or use the "ADD a CEMS Monitoring Location" link to create a new one). On the bottom of Add/Edit CEMS Monitoring Location page, use the "ADD/REMOVE a process unit that exhausts to this CEMS Monitoring Location" link to select this unit. |
CML-001 | N | Screen Error | CEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL. |
CML-002 | N | Screen Error | Configuration type. This data element is required. Please enter the required data or click CANCEL. |
CML-007 | N | Data Completeness | Total carbon dioxide (CO2) emissions measured by the CEMS. This data element is required. |
CML-007X | N | Screen Error | Total carbon dioxide (CO2) emissions measured by the CEMS (or applicable Part 75 methodology). This data element must be greater than or equal to biogenic carbon dioxide emissions. |
CML-012 | N | Screen Error | You have entered a calculation methodology start date that is later than the calculation methodology end date. You must correct this before continuing. |
CML-013 | N | Screen Error | Calculation methodology start date. This data element is required. Please enter the required data or click CANCEL. |
CML-014 | N | Screen Error | Calculation methodology end date. This data element is required. Please enter the required data or click CANCEL. |
CML-016 | N | Screen Error | Carbon dioxide emissions in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-018 | N | Screen Error | Carbon dioxide emissions in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-020 | N | Screen Error | Carbon dioxide emissions in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-022 | N | Screen Error | Carbon dioxide emissions in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-027a | N | Data Completeness | Fraction of nitrous oxide emissions from CML. This data element is required. |
CML-034 | N | Screen Error | Total number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-035 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-036 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-037 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-038 | N | Screen Error | Total number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-039 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-040 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-041 | N | Screen Error | The total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing. |
CML-043 | N | Data Completeness | The total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This data element is required. |
CML-046 | N | Data Completeness | CEMS Monitoring Location process units. You did not select any process unit(s) for this CML. |
CML-047a | N | Data Completeness | Fraction of methane emissions from CML. This data element is required. |
CML-051 | N | Data Completeness | Total Non-biogenic carbon dioxide emissions. This data element is required. |
CML-052 | N | Data Completeness | Total Biogenic carbon dioxide emissions. This data element is required. |
CML-053 | N | Data Completeness | Total methane (CH4) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. |
CML-054 | N | Data Completeness | Total nitrous oxide (N2O) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. |
CML-055 | N | Data Completeness | Total carbon dioxide (CO2) emissions measured by the CEMS. This data element is required. |
CML-056 | N | Screen Error | Total annual CO2 mass emissions (biogenic and non-biogenic) measured by the CEMS. This data element must be greater than or equal to biogenic carbon dioxide emissions. |
CML-057 | N | Data Completeness | Total number of source operating hours in the reporting year. This data element is required. |
CML-058 | N | Data Completeness | The total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This data element is required. |
CML-059 | N | Screen Error | You have entered a calculation methodology start date that is later than the calculation methodology end date. Please revise and make sure the Start Date is less than the End Date. |
CML-060 | N | Screen Error | Calculation methodology start date. This data element is required. Please enter the required data or click CANCEL. |
CML-061 | N | Screen Error | Configuration type. This data element is required. Please enter the required data or click CANCEL. |
CML-062 | N | Screen Error | Calculation methodology end date. This data element is required. Please enter the required data or click CANCEL. |
CML-063 | N | Data Completeness | Carbon dioxide emissions measured in Quarter 1. This data element is required. |
CML-064 | N | Screen Error | Carbon dioxide emissions measured in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-065 | N | Data Completeness | Carbon dioxide emissions measured in Quarter 2. This data element is required. |
CML-066 | N | Screen Error | Carbon dioxide emissions measured in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-067 | N | Data Completeness | Carbon dioxide emissions measured in Quarter 3. This data element is required. |
CML-068 | N | Screen Error | Carbon dioxide emissions measured in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-069 | N | Data Completeness | Carbon dioxide emissions measured in Quarter 4. This data element is required. |
CML-070 | N | Screen Error | Carbon dioxide emissions measured in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
CML-071 | N | Screen Error | CEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL. |
CML-072 | N | Data Completeness | Type(s) of fuel combusted in the unit(s) monitored by the CEMS. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. |
CML-073 | N | Screen Error | Total methane (CH4) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL. |
CML-074 | N | Screen Error | Total nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL. |
CML-075 | N | Screen Error | Types of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL. |
CML-076 | N | Screen Error | Total methane (CH4) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL. |
CML-077 | N | Screen Error | Total nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL. |
CML-078 | N | Screen Error | Types of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL. |
CML-082 | N | Data Completeness | Carbon dioxide emissions attributable to combustion. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. |
CML-083 | N | Screen Error | Carbon dioxide emissions attributable to combustion. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported emissions and leave the types of emissions field blank, or click CANCEL. |
CML-086 | N | Screen Error | The Calculation Methodology Start Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year. |
CML-087 | N | Screen Error | The Calculation Methodology Start Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year. |
CML-088 | N | Screen Error | The Calculation Methodology End Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year. |
CML-089 | N | Screen Error | The Calculation Methodology End Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year. |
IVT-N001 | N | Screen Error | Annual average decimal mass fraction of carbonate-based mineral in carbonate-based raw material. This data element is required. Please enter the required data or click CANCEL. |
IVT-N002 | N | Screen Error | Annual average decimal mass fraction of carbonate-based mineral in carbonate-based raw material. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing. |
IVT-N004 | N | Screen Error | Annual amount of carbonate-based raw material charged to furnace. This data element is required. Please enter the required data or click CANCEL. |
IVT-N005 | N | Screen Error | Annual amount of carbonate-based raw material charged to furnace. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
IVT-N007 | N | Screen Error | Decimal fraction of calcination achieved for carbonate-based raw material. This data element is required. Please enter the required data or click CANCEL. |
IVT-N008 | N | Screen Error | Decimal fraction of calcination achieved for carbonate-based raw material. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing. |
IVT-N012 | N | Data Completeness | You have not yet added any equation inputs data for this raw material charged to the furnace. Please use the Inputs Verifier Tool to enter equation inputs for each raw material and calculate a result for this furnace. |
N001 | N | Data Completeness | Annual quantity of limestone charged to all furnaces. This data element is required. If limestone was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N002 | N | Screen Error | Annual quantity of limestone charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N004 | N | Data Completeness | Annual quantity of dolomite charged to all furnaces. This data element is required. If dolomite was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N005 | N | Screen Error | Annual quantity of dolomite charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N007 | N | Data Completeness | Annual quantity of sodium carbonate charged to all furnaces. This data element is required. If sodium carbonate was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N008 | N | Screen Error | Annual quantity of sodium carbonate charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N010 | N | Data Completeness | Annual quantity of barium carbonate charged to all furnaces. This data element is required. If barium carbonate was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N011 | N | Screen Error | Annual quantity of barium carbonate charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N012 | N | Data Completeness | Annual quantity of potassium carbonate charged to all furnaces. This data element is required. If potassium carbonate was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N013 | N | Screen Error | Annual quantity of potassium carbonate charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N014 | N | Data Completeness | Annual quantity of lithium carbonate charged to all furnaces. This data element is required. If lithium carbonate was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N015 | N | Screen Error | Annual quantity of lithium carbonate charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N016 | N | Data Completeness | Annual quantity of strontium carbonate charged to all furnaces. This data element is required. If strontium carbonate was not charged to any furnaces at your facility during the reporting year, please enter zero. |
N017 | N | Screen Error | Annual quantity of strontium carbonate charged to all furnaces. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N018 | N | Screen Error | Please make a selection or click CANCEL. |
N019 | N | Data Completeness | Annual quantity of glass produced by the furnace. This data element is required. |
N020 | N | Screen Error | Annual quantity of glass produced by the furnace. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N022 | N | Screen Error | Selection of at least one raw material type is required for each furnace. Please select one or more raw material types or click CANCEL. |
N023 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of limestone. This data element is required. |
N024 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of limestone. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N025 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of limestone. This data element is required. |
N026 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of limestone. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N027 | N | Data Completeness | Method used to determine the fraction of calcination for limestone. This data element is required. |
N028 | N | Data Completeness | Method used to determine the fraction of calcination for limestone. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N029 | N | Data Completeness | Mass fraction verification test data for limestone. These data elements are required. |
N030 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of dolomite. This data element is required. |
N031 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of dolomite. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N032 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of dolomite. This data element is required. |
N033 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of dolomite. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N034 | N | Data Completeness | Method used to determine the fraction of calcination for dolomite. This data element is required. |
N035 | N | Data Completeness | Method used to determine the fraction of calcination for dolomite. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N036 | N | Data Completeness | Mass fraction verification test data for dolomite. These data elements are required. |
N037 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of sodium carbonate. This data element is required. |
N038 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of sodium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N039 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of sodium carbonate. This data element is required. |
N040 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of sodium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N041 | N | Data Completeness | Method used to determine the fraction of calcination for sodium carbonate. This data element is required. |
N042 | N | Data Completeness | Method used to determine the fraction of calcination for sodium carbonate. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N043 | N | Data Completeness | Mass fraction verification test data for sodium carbonate. These data elements are required. |
N044 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of barium carbonate. This data element is required. |
N045 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of barium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N046 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of barium carbonate. This data element is required. |
N047 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of barium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N048 | N | Data Completeness | Method used to determine the fraction of calcination for barium carbonate. This data element is required. |
N049 | N | Data Completeness | Method used to determine the fraction of calcination for barium carbonate. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N050 | N | Data Completeness | Mass fraction verification test data for barium carbonate. These data elements are required. |
N051 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of potassium carbonate. This data element is required. |
N052 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of potassium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N053 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of potassium carbonate. This data element is required. |
N054 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of potassium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N055 | N | Data Completeness | Method used to determine the fraction of calcination for potassium carbonate. This data element is required. |
N056 | N | Data Completeness | Method used to determine the fraction of calcination for potassium carbonate. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N057 | N | Data Completeness | Mass fraction verification test data for potassium carbonate. These data elements are required. |
N058 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of lithium carbonate. This data element is required. |
N059 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of lithium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N060 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of lithium carbonate. This data element is required. |
N061 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of lithium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N062 | N | Data Completeness | Method used to determine the fraction of calcination for lithium carbonate. This data element is required. |
N063 | N | Data Completeness | Method used to determine the fraction of calcination for lithium carbonate. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N064 | N | Data Completeness | Mass fraction verification test data for lithium carbonate. These data elements are required. |
N065 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly quantity of strontium carbonate. This data element is required. |
N066 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly quantity of strontium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N067 | N | Data Completeness | Number of months in the reporting year that missing data procedures were followed to measure monthly mass fraction of strontium carbonate. This data element is required. |
N068 | N | Screen Error | The number of months in the reporting year that missing data procedures were followed to measure a monthly mass fraction of strontium carbonate. This value should be reported as a number and should be within the range of 0 to 12 months. The value you provided is outside that range. You must correct the current value before continuing. |
N069 | N | Data Completeness | Method used to determine the fraction of calcination for strontium carbonate. This data element is required. |
N070 | N | Data Completeness | Method used to determine the fraction of calcination for strontium carbonate. You selected "other" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N071 | N | Data Completeness | Mass fraction verification test data for strontium carbonate. These data elements are required. |
N072 | N | Data Completeness | Annual carbon dioxide emissions from the furnace. This data element is required. |
N073 | N | Screen Error | Annual carbon dioxide emissions from the furnace. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing. |
N075 | N | Screen Error | Mass fraction verification test date. This data element is required. |
N076 | N | Screen Error | Mass fraction verification test method(s) and any variations used in the analysis. This data element is required. |
N077 | N | Screen Error | The mass fraction of the sample. This data element is required. |
N078 | N | Screen Error | The mass fraction of the sample, expressed as a decimal fraction, should be within the range of 0 to 1. The value you provided is outside that range. You must correct the current value before continuing. |
N079 | N | Screen Error | The mass fraction of the sample. This data element is required. |
N080 | N | Screen Error | The mass fraction of the sample, expressed as a decimal fraction, should be within the range of 0 to 1. The value you provided is outside that range. You must correct the current value before continuing. |
N081 | N | Screen Error | The mass fraction of the sample. This data element is required. |
N082 | N | Screen Error | The mass fraction of the sample, expressed as a decimal fraction, should be within the range of 0 to 1. The value you provided is outside that range. You must correct the current value before continuing. |
N083 | N | Screen Error | The mass fraction of the sample. This data element is required. |
N084 | N | Screen Error | The mass fraction of the sample, expressed as a decimal fraction, should be within the range of 0 to 1. The value you provided is outside that range. You must correct the current value before continuing. |
N085 | N | Screen Error | The mass fraction of the sample. This data element is required. |
N086 | N | Screen Error | The mass fraction of the sample, expressed as a decimal fraction, should be within the range of 0 to 1. The value you provided is outside that range. You must correct the current value before continuing. |
N087 | N | Screen Error | Enter Own Result for Result (ECO2). This data element is required if you select Enter/Report Alternate Result. |
N088 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for limestone. This data element is required. |
N089 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for limestone. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N090 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for dolomite. This data element is required. |
N091 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for dolomite. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N092 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for sodium carbonate. This data element is required. |
N093 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for sodium carbonate. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N094 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for barium carbonate. This data element is required. |
N095 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for barium carbonate. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N096 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for potassium carbonate. This data element is required. |
N097 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for potassium carbonate. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N098 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for lithium carbonate. This data element is required. |
N099 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for lithium carbonate. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N100 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for strontium carbonate. This data element is required. |
N101 | N | Data Completeness | The method (and any variations) used to determine the mass fraction for strontium carbonate. You selected "Test Method" from the pick list provided, but failed to provide any additional information in the text box provided. This data element is required. |
N200 | N | Data Completeness | Annual quantity of limestone charged to furnace (tons). This data element is required. |
N201 | N | Data Completeness | Annual quantity of dolomite charged to furnace (tons). This data element is required. |
N202 | N | Data Completeness | Annual quantity of sodium carbonate charged to furnace (tons). This data element is required. |
N203 | N | Data Completeness | Annual quantity of barium carbonate charged to furnace (tons). This data element is required. |
N204 | N | Data Completeness | Annual quantity of potassium carbonate charged to furnace (tons). This data element is required. |
N205 | N | Data Completeness | Annual quantity of lithium carbonate charged to furnace (tons). This data element is required. |
N206 | N | Data Completeness | Annual quantity of strontium carbonate charged to furnace (tons). This data element is required. |
N207 | N | Data Completeness | You have selected Subpart N for reporting, but you have not yet added a furnace. |