Critical Validation Checks for Subpart L

Certain validation checks which are considered critical errors must be corrected before you can successfully generate your submission package or upload your XML-based submission. These checks are presented to the reporter when they attempt to generate or regenerate their submission or after they attempt to upload an XML-based submission. These checks are signified with a stop sign in your validation report.   The table below provides a list of critical errors.   Additional technical information that may assist XML uploaders is also available at XML Upload Critical Errors.  If you feel that you have triggered one of these checks in error, or if there’s a reason why your report should be submitted despite the check being triggered, you may submit a request to the e-GGRT Help Desk at GHGReporting@epa.gov.

CODESUBPARTTYPEMESSAGE_TEXT
IVT-L0001LScreen ErrorGHGRP ID (Introduction tab, cell D7). This data element is required and must be equal to the GHGRP ID for the facility.
IVT-L0002LScreen ErrorReporting Period (Introduction tab, cell D8). This data element is required and must be equal to the expected reporting year.
IVT-L0003LScreen ErrorDid the facility produce only one fluorinated gas product, including fluorinated gas products that are intermediates (Introduction tab, cell L13). This data element is required.
IVT-L0004LScreen ErrorBecause you indicated that the facility produced only one fluorinated gas product in Cell L13, you must indicate if facility emissions include one or more major F-GHG constituents of a Fluorinated gas product that is sold or transferred to another person (Introduction tab, cell L14). This data element is required.
IVT-L0005LScreen ErrorDid the facility destroy previously produced fluorinated GHGs in destruction processes that are not part of a fluorinated gas production process or fluorinated gas transformation process (Introduction tab, cell L23). This data element is required.
IVT-L0006LScreen ErrorDid the facility vent residual fluorinated GHGs from containers (Introduction tab, cell L18). This data element is required.
IVT-L0007LScreen ErrorProcess - generic name to be reported in e-GGRT (Production Transformation tab Part 1, Column C, row number {1}). This data element is required.
IVT-L0008LScreen ErrorOperating Scenario (Production Transformation tab Part 1, Column D, row number {1}). This data element is required.
IVT-L0009LScreen ErrorProcess Vent (Production Transformation tab Part 1, Column E, row number {1}). This data element is required.
IVT-L0010LScreen ErrorEF or ECF Method selection (Production Transformation tab Part 1, Column F, row number {1}). This data element is required.
IVT-L0011LScreen ErrorWere emissions from this process vented to a destruction device during the year (Production Transformation tab Part 1, Column G, row number {1}). This data element is required.
IVT-L0012LScreen ErrorDid you conduct emissions testing before the destructive device (Production Transformation tab Part 1, Column H, row number {1}). This data element is required.
IVT-L0013LScreen ErrorF-GHG (Production Transformation tab Part 1, Column I, row number {1}). This data element is required.
IVT-L0014LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column I, Other f-GHG Name (Production Transformation tab Part 1, Column K, row number {1}) is required.
IVT-L0015LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column I, Other CASRN (Production Transformation tab Part 1, Column L, row number {1}) is required.
IVT-L0016LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column I, Other Chemical Formula (Production Transformation tab Part 1, Column M, row number {1}) is required.
IVT-L0017LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column I, Specify F-GHG Group for Other F-GHG Not Listed for Purposes of Estimating GWP (Production Transformation tab Part 1, Column N, row number {1}) is required.
IVT-L0018LScreen ErrorBecause you have indicated use of Equation L-21, Emission factor (controlled) for fluorinated GHG f emitted from process vent v during process i, operating scenario j, based on testing after the destruction device (Production Transformation tab Part 1, Column R, row number {1}) is required.
IVT-L0019LScreen ErrorBecause you have indicated use of Equation L-21, Controlled Activity: Total process feed, process production, or other process activity during the year for which the process vent is vented to the properly functioning destruction device (Production Transformation tab Part 1, Column S, row number {1}) is required.
IVT-L0020LScreen ErrorBecause you have indicated use of Equation L-21, Emission calculation factor (uncontrolled) for fluorinated GHG f emitted from process vent v during process i, operating scenario j during periods when the process vent is NOT vented to the properly functioning destruction device (Production Transformation tab Part 1, Column T, row number {1}) is required.
IVT-L0021LScreen ErrorBecause you have indicated use of Equation L-21, Uncontrolled Activity: Total process feed, process production, or other process activity during the year for which the process vent is NOT vented to the properly functioning destruction device (Production Transformation tab Part 1, Column U, row number {1}) is required.
IVT-L0022LScreen ErrorBecause you have indicated use of Equation L-22, Emission factor (uncontrolled) for fluorinated GHG f emitted from process vent v during process i, operating scenario j (Production Transformation tab Part 1, Column W, row number {1}) is required.
IVT-L0023LScreen ErrorBecause you have indicated use of Equation L-22, Uncontrolled Activity: Total process feed, process production, or other process activity for process i, operating scenario j, during the year for which the process vent is NOT vented to the properly functioning destruction device (Production Transformation tab Part 1, Column X, row number {1}) is required.
IVT-L0024LScreen ErrorBecause you have indicated use of Equation L-22, Controlled Activity: Total process feed, process production, or other process activity for process i, operating scenario j, during the year for which the process vent is vented to the properly functioning destruction device (Production Transformation tab Part 1, Column Y, row number {1}) is required.
IVT-L0025LScreen ErrorBecause you have indicated use of Equation L-22, Demonstrated destruction efficiency of the destruction device for the fluorinated GHG f (Production Transformation tab Part 1, Column Z, row number {1}) is required.
IVT-L0026LScreen ErrorBecause you have indicated use of Equation L-26, Emission calculation factor for fluorinated GHG f emitted from process vent v during process i, operating scenario j (Production Transformation tab Part 1, Column AB, row number {1}) is required.
IVT-L0027LScreen ErrorBecause you have indicated use of Equation L-26, Activity: Process feed, process production, or other process activity for process i, operating scenario j, during the year (Production Transformation tab Part 1, Column AC, row number {1}) is required.
IVT-L0028LScreen ErrorBecause you have indicated use of Equation L-27, Emission calculation factor for fluorinated GHG f emitted from process vent v during process i, operating scenario j (Production Transformation tab Part 1, Column AE, row number {1}) is required.
IVT-L0029LScreen ErrorBecause you have indicated use of Equation L-27, Uncontrolled Activity: Total process feed, process production, or other process activity for process i, operating scenario j, during the year for which the process vent is NOT vented to the properly functioning destruction device (Production Transformation tab Part 1, Column AF, row number {1}) is required.
IVT-L0030LScreen ErrorBecause you have indicated use of Equation L-27, Controlled Activity: Total process feed, process production, or other process activity for process i, operating scenario j, during the year for which the process vent is vented to the properly functioning destruction device (Production Transformation tab Part 1, Column AG, row number {1}) is required.
IVT-L0031LScreen ErrorBecause you have indicated use of Equation L-27, Demonstrated destruction efficiency of the destruction device for the fluorinated GHG f (Production Transformation tab Part 1, Column AH, row number {1}) is required.
IVT-L0032LScreen ErrorMass of fluorinated GHG f emitted from equipment leaks for pieces of equipment for process i, annually (Production Transformation tab Part 2, Column G, row number {1}) is required.
IVT-L0033LScreen ErrorIs the F-GHG a Major Constituent of a product that is sold or transferred to another person (Production Transformation tab Part 3, Column E, row number {1}) is required.
IVT-L0034LScreen ErrorContainer Type/Size Description (Container Venting tab, Column C, row number {1}). This data element is required.
IVT-L0035LScreen ErrorF-GHG (Container Venting tab, Column D, row number {1}). This data element is required.
IVT-L0036LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other f-GHG Name (Container Venting tab, Column F, row number {1}) is required.
IVT-L0037LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other CASRN (Container Venting tab, Column G, row number {1}) is required.
IVT-L0038LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other Chemical Formula (Container Venting tab, Column H, row number {1}) is required.
IVT-L0039LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Specify F-GHG Group for Other F-GHG Not Listed for Purposes of Estimating GWP (Container Venting tab, Column I, row number {1}) is required.
IVT-L0040LScreen ErrorDo you directly measure the amount of f-GHG in each container, or did you develop a heel factor (Container Venting tab, Column K, row number {1}). This data element is required.
IVT-L0041LScreen ErrorBecause you have indicated that you directly measure the amount of f-GHG in each container in Column K, total mass emitted (Container Venting tab, Column L, row number {1}) is required.
IVT-L0042LScreen ErrorBecause you have indicated that you developed a heel factor in Column K, Facility-wide heel factor (Container Venting tab, Column M, row number {1}) is required.
IVT-L0043LScreen ErrorBecause you have indicated that you developed a heel factor in Column K, Number of containers returned to the fluorinated gas production facility (Container Venting tab, Column N, row number {1}) is required.
IVT-L0044LScreen ErrorBecause you have indicated that you developed a heel factor in Column K, Full capacity of containers (Container Venting tab, Column O, row number {1}) is required.
IVT-L0045LScreen ErrorDestruction Device (Destruction of Prev. Produced tab, Column C, row number {1}). This data element is required.
IVT-L0046LScreen ErrorF-GHG (Destruction of Prev. Produced tab, Column D, row number {1}). This data element is required.
IVT-L0047LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other f-GHG Name (Destruction of Prev. Produced tab, Column F, row number {1}) is required.
IVT-L0048LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other CASRN (Destruction of Prev. Produced tab, Column G, row number {1}) is required.
IVT-L0049LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Other Chemical Formula (Destruction of Prev. Produced tab, Column H, row number {1}) is required.
IVT-L0050LScreen ErrorBecause you have selected \'Other f-GHG chemical not listed\' in Column D, Specify F-GHG Group for Other F-GHG Not Listed for Purposes of Estimating GWP (Destruction of Prev. Produced tab, Column I, row number {1}) is required.
IVT-L0051LScreen ErrorMass of f-GHG that was previously produced and fed annually into the destruction device (Destruction of Prev. Produced tab, Column K, row number {1}). This data element is required.
IVT-L0052LScreen ErrorDestruction efficiency of the destruction device (Destruction of Prev. Produced tab, Column L, row number {1}). This data element is required.
IVT-L0053LScreen ErrorYou have not provided any information in Part 1 (Equation Selection for Process Vents) of the Production Transformation tab.
IVT-L0054LScreen ErrorYou have not provided any information in Part 2 (Process Vent and Equipment Leak Totals by F-GHG and Process) of the Production Transformation tab.
IVT-L0055LScreen ErrorYou have not provided any information in Part 3 (Identification of Emitted F-GHGs as Major Constituents in Products Sold or Transferred) of the Production Transformation tab.
IVT-L0056LScreen ErrorYou have indicated that the facility vented residual fluorinated GHGs from containers (Introduction tab, cell L18), but you have not provided any information in the Container Venting tab.
IVT-L0057LScreen ErrorYou have indicated that the facility destroyed previously produced fluorinated GHGs in destruction processes that are not part of a fluorinated gas production process or fluorinated gas transformation process (Introduction tab, cell L23), but you have not provided any information in the Destruction of Prev. Produced tab.
IVT-L0058LData QualityDemonstrated destruction efficiency of the destruction device for fluorinated GHG. Because you have indicated use of the EF Method (Equation L-21 or L-22) in Column F of the Production and Transformation tab and have also indicated that emissions were not vented to a destruction device in Column G of the Production and Transformation tab, you must report a value of zero for the demonstrated destruction efficiency of the destruction device for fluorinated GHG in Column Z of the same tab. Please double check this value and revise.
IVT-L0063LScreen ErrorFacility name. This data element is required.
L0001LScreen ErrorTotal Facility F-GHG Emissions (metric tons of CO2e). This data element is required.
L0012LData CompletenessEquipment Leak Emissions Estimation Method. You have selected mass balance mass emissions determination approach and an equipment leak emissions estimation method. Please do not select an equipment leak emissions estimation method if you only used the mass balance approach.
L0013LData CompletenessEquipment Leak Emissions Estimation Method. You have selected process-vent-specific emission factor but not selected an equipment leak emissions estimation method. Please select an equipment leak emissions estimation method.
L0014LData CompletenessEquipment Leak Emissions Estimation Method. You have selected process-vent-specific emission calculation factor but not selected an equipment leak emissions estimation method. Please select an equipment leak emissions estimation method.
L0015LData CompletenessEquipment Leak Emissions Estimation Method. The number of methods you have provided is outside the EPA estimated range for this data element. Please double check these methods and revise, if necessary. If you believe it to be correct, please submit the selections as is.
L0016LData CompletenessFacility F-GHG Emissions Calculated using default GWP of 2,000 (metric tons of CO2e). This data element is required.
L0017LData CompletenessFacility F-GHG Emissions Calculated using default GWP of 10,000 (metric tons of CO2e). This data element is required.
L0018LData CompletenessFacility F-GHG Emissions Calculated using your best estimate of the GWP (metric tons of CO2e). This data element is required.
L0019LData CompletenessYou have not yet entered F-GHG facility summary information for this fluorinated gas production facility.
L0020LScreen ErrorDid the facility produce only one fluorinated gas product, including fluorinated gas products that are intermediates? This data element is required.
L0021LScreen ErrorDid facility emissions include one or more major F-GHG constituents of a Fluorinated gas product that is sold or transferred to another person? This data element is required.
L0022LScreen ErrorDid the facility emit 1,000 or more metric tons of CO2e of any one fluorinated GHG from production and transformation processes, summed across the facility as a whole? This data element is required.
L0023LScreen ErrorDid the facility destroy previously produced fluorinated GHGs in destruction processes that are not part of a fluorinated gas production process or fluorinated gas transformation process? This data element is required.
L0024LScreen ErrorDid the facility vent residual fluorinated GHGs from containers? This data element is required.
L0025LData CompletenessYou have not yet added any production and transformation processes.
L0026LScreen ErrorUnique Process Name/Identifier. This data element is required.
L0027LScreen ErrorUnique Process Name/Identifier. The same name or identifier already exists for this facility.
L0028LScreen ErrorProcess Type. This data element is required.
L0029LScreen ErrorMethod the Facility used to determine emissions of fluorinated GHG from the process vents. This data element is required.
L0030LScreen ErrorF GHG Name. This data element is required.
L0031LScreen ErrorF GHG Name. The same name already exists for this facility.
L0032LScreen ErrorF GHG Chemical Formula. This data element is required.
L0033LScreen ErrorChemical Abstract Registry Number (CAS No.). This data element is required.
L0034LScreen ErrorYou did not select the Fluorinated GHG Group of which this "Other" F-GHG is a member.
L0035LScreen ErrorPlease select one or more F-GHG groups or click CANCEL.
L0036LData CompletenessProduction and transformation process emissions for individual F GHG. This data element is required.
L0037LData CompletenessWere the annual emissions based on a missing data procedure? This data element is required.
L0038LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0039LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions. This data element is required.
L0040LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0041LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required.
L0042LData CompletenessProduction and transformation process emissions for f-GHG Group. This data element is required.
L0043LData CompletenessEmissions from Destruction of Previously Produced F GHGs. This data element is required.
L0044LData CompletenessEmissions of F-GHGs Vented from containers returned from the field. This data element is required.
L0045LData CompletenessWere the annual process emissions of one or more F-GHG groups based on a missing data procedure? This data element is required.
L0046LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0047LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions. This data element is required.
L0048LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0049LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required.
L0050LData CompletenessGWP-weighted mass of all fluorinated GHGs in this group. This data element is required.
L0051LData CompletenessWere the annual emissions from process vents based on a missing data procedure? This data element is required.
L0052LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0053LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions. This data element is required.
L0054LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0055LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required. If the data element is not reportable enter \'NA\'
L0056LData CompletenessGWP-weighted mass of all fluorinated GHGs in this group emitted from all process vents combined. This data element is required.
L0057LData CompletenessWere the annual emissions from equipment leaks based on a missing data procedure? This data element is required.
L0058LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0059LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions. This data element is required.
L0060LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0061LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required. If the data element is not reportable enter \'NA\'
L0062LData CompletenessGWP-weighted mass of all fluorinated GHGs in this group emitted from equipment leaks. This data element is required.
L0063LScreen ErrorCharacterize the process. This data element is required.
L0064LData CompletenessYou have not yet added any f-GHGs for production and transformation.
L0065LData CompletenessYou have not yet added any f-GHG groups.
L0066LData CompletenessYou have not yet added any f-GHG groups for this process.
L0067LScreen ErrorProduction and transformation process emissions for individual F GHG. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0068LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0069LScreen ErrorProduction and transformation process emissions for f-GHG Group. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0070LScreen ErrorEmissions from Destruction of Previously Produced F GHGs. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0071LScreen ErrorEmissions of F-GHGs Vented from containers returned from the field. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0072LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0073LScreen ErrorGWP-weighted mass of all fluorinated GHGs in this group. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0074LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0075LScreen ErrorGWP-weighted mass of all fluorinated GHGs in this group emitted from all process vents combined. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0076LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0077LScreen ErrorGWP-weighted mass of all fluorinated GHGs in this group emitted from equipment leaks. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
L0078LData CompletenessYou have not yet added any f-GHGs for destruction.
L0079LData CompletenessYou have not yet added any f-GHGs for venting.
L0080LData CompletenessMethod used to estimate the total mass of fluorine in destroyed or recaptured streams. This data element is required.
L0081LData CompletenessFor this generically-identified process, report the methods used to determine the mass emissions of each fluorinated GHG group emitted from equipment leaks. You must select at least one check box.
L0202LScreen ErrorMade changes to the pick list and selected option to add an unlisted gas. If adding an unlisted gas, do not modify the pick list. Selections from previous sessions can be left alone.
L0203LScreen ErrorMade changes to the pick list and selected option to add an unlisted gas. If adding an unlisted gas, do not modify the pick list. Selections from previous sessions can be left alone.
L0204LScreen ErrorMade changes to the pick list and selected option to add an unlisted gas. If adding an unlisted gas, do not modify the pick list. Selections from previous sessions can be left alone.
L0300LData CompletenessPlease enter facility name
L0500LScreen ErrorDid the facility produce only one fluorinated gas product, including fluorinated gas products that are intermediates? This data element is required.
L0501LScreen ErrorDid facility emissions include one or more major F-GHG constituents of a Fluorinated gas product that is sold or transferred to another person? This data element is required.
L0502LScreen ErrorDid the facility destroy previously produced fluorinated GHGs in destruction processes that are not part of a fluorinated gas production process or fluorinated gas transformation process? This data element is required.
L0503LScreen ErrorDid the facility vent residual fluorinated GHGs from containers? This data element is required.
L0504LScreen ErrorAnother f-GHG already exists in the database for the CAS Number supplied for Name or ID {1}, but exists with a different default GWP than the value uploaded. The previous value that was uploaded will be used when calculating the GWP. Please verify that you selected the correct default GWP in the select box. If the value you supplied is correct, you must call the Help Desk and ask to change the default GWP of the other f-GHG referenced in your Subpart L upload that already exists in the database. Also, please have your spreadsheet open to answer any questions.
L0505LScreen ErrorYou cannot add this greenhouse gas because the CAS Registry Number you have provided for this &#39;other&#39; gas matches with an existing 40 CFR Part 98 Table A-1 gas, or it matches with an &#39;other&#39; gas that has already been added. It is possible it is included in the selection list provided, but with a different chemical name than the one you are using. The gas with the matching CAS Registry Number is identified within e-GGRT as follows: CAS Registry Number: {1}; Gas Name: {2}; Chemical Formula: {3}. If you would like to select this gas, click CANCEL and locate the gas on the selection list provided. If you are unable to locate this gas on the selection list provided, please <a href=http://www.ccdsupport.com/confluence/display/help/Contact+the+Help+Desk+-+Issues+Related+to+the+Identification+of+Specific+f-GHGs target=_blank>contact the GHGRP Help Desk</a>.
L0506LData CompletenessYou have not yet uploaded an equation inputs form. Please upload an equation inputs form for this Fluorinated Gas Production facility.
L0507LData CompletenessWas the Destruction of Previously Produced information based on a missing data procedure? This data element is required.
L0508LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0509LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions from destruction device. This data element is required.
L0510LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions from destruction device. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0511LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0512LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required. If the data element is not reportable enter \'NA\'
L0520LData CompletenessWas the container information based on a missing data procedure? This data element is required.
L0521LData CompletenessData element for which missing data procedures were used, and the reason for the missing data. This data element is required.
L0522LData CompletenessNumber of hours a missing data procedure was used to determine F-GHG emissions from container. This data element is required.
L0523LScreen ErrorNumber of hours a missing data procedure was used to determine F-GHG emissions from container. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
L0524LData CompletenessProvide the method used to estimate the missing data. This data element is required.
L0525LData CompletenessIf the data element is reportable under subpart L, provide estimates of missing data. This data element is required. If the data element is not reportable enter \'NA\'


 Back

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2023.R.01)