Critical Validation Checks for Subpart CC

Certain validation checks which are considered critical errors must be corrected before you can successfully generate your submission package or upload your XML-based submission. These checks are presented to the reporter when they attempt to generate or regenerate their submission or after they attempt to upload an XML-based submission. These checks are signified with a stop sign in your validation report.   The table below provides a list of critical errors.   Additional technical information that may assist XML uploaders is also available at XML Upload Critical Errors.  If you feel that you have triggered one of these checks in error, or if there’s a reason why your report should be submitted despite the check being triggered, you may submit a request to the e-GGRT Help Desk at GHGReporting@epa.gov.

CODESUBPARTTYPEMESSAGE_TEXT
CC006CCData CompletenessTotal number of soda ash process lines not monitored by CEMS. This data element is required.
CC007CCScreen ErrorTotal number of soda ash process lines not monitored by CEMS. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC008CCData CompletenessYou have added Subpart CC, but have not yet added a line.
CC009CCScreen ErrorIs this manufacturing line\'s emissions monitored using a CEMS?. This data element is required. Please enter the required data or click CANCEL.
CC011CCScreen ErrorCalculation method used to estimate CO2 process emissions. This data element is required.
CC013CCData CompletenessAnnual production of soda ash. This data element is required.
CC014CCScreen ErrorAnnual production of soda ash. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC016CCData CompletenessAnnual production capacity of soda ash. This data element is required.
CC017CCScreen ErrorAnnual production capacity of soda ash. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC019CCData CompletenessAnnual CO2 process emissions for the manufacturing line. This data element is required.
CC020CCScreen ErrorAnnual CO2 emissions for the manufacturing line. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC021CCData CompletenessThe number of months that missing data procedures were followed to determine the process vent flow rate from mine water stripper/evaporator. This data element is required.
CC022CCScreen ErrorTotal number of soda ash manufacturing lines not monitored by CEMS. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC025CCScreen ErrorThe number of times that missing data procedures were followed to repeat test to determine the stack gas volumetric flow during the performance test. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC027CCScreen ErrorThe number of times that missing data procedures were followed to repeat test to determine the hourly CO2 concentration. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC029CCScreen ErrorThe number of times that missing data procedures were followed to repeat test to determine the average process vent flow rate during the performance test. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC030CCData CompletenessAnnual CO2 process emissions for the manufacturing line. This data element is required.
CC031CCScreen ErrorAnnual CO2 emissions for the manufacturing line. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC032CCData CompletenessThe number of months that missing data procedures were followed to determine the monthly mass of soda ash. This data element is required.
CC035CCData CompletenessThe number of weeks that missing data procedures were followed to determine the inorganic carbon content of soda ash. This data element is required.
CC036CCScreen ErrorThe number of weeks that missing data procedures were followed to determine the inorganic carbon content of soda ash. You must enter a value that is greater than or equal to zero and less than or equal to 52. You must correct the current value before continuing.
CC038CCData CompletenessAnnual CO2 process emissions for the manufacturing line. This data element is required.
CC039CCScreen ErrorAnnual CO2 emissions for the manufacturing line. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC040CCData CompletenessThe number of months that missing data procedures were followed to determine the monthly mass of trona. This data element is required.
CC043CCData CompletenessThe number of weeks that missing data procedures were followed to determine the inorganic carbon content of trona. This data element is required.
CC044CCScreen ErrorThe number of weeks that missing data procedures were followed to determine the inorganic carbon content of trona. You must enter a value that is greater than or equal to zero and less than or equal to 52. You must correct the current value before continuing.
CC047CCData CompletenessAnnual consumption of trona for each manufacturing line. This data element is required.
CC048CCScreen ErrorAnnual consumption of trona for each manufacturing line. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC050CCData CompletenessAnnual consumption of liquid alkaline for each manufacturing line. This data element is required.
CC051CCScreen ErrorAnnual consumption of liquid alkaline for each manufacturing line. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC053CCData CompletenessAnnual production of soda ash. This data element is required.
CC054CCScreen ErrorAnnual production of soda ash. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC056CCData CompletenessAnnual production capacity of soda ash. This data element is required.
CC057CCScreen ErrorAnnual production capacity of soda ash. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC059CCData CompletenessThe annual process vent flow rate from the mine water stripper/evaporator. This data element is required.
CC060CCScreen ErrorThe annual process vent flow rate from the mine water stripper/evaporator. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC061CCData CompletenessThe average process vent flow rate from the mine water stripper/evaporator. This data element is required.
CC062CCScreen ErrorThe average process vent flow rate from the mine water stripper/evaporator. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC063CCData CompletenessThe hourly CO2 concentration during the performance test. This data element is required.
CC064CCScreen ErrorThe hourly CO2 concentration during the performance test. You must enter a value that is greater than or equal to zero and less than or equal to 100. You must correct the current value before continuing.
CC065CCData CompletenessThe stack gas volumetric flow rate during the performance test. This data element is required.
CC066CCScreen ErrorThe stack gas volumetric flow rate during the performance test. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC067CCData CompletenessThe CO2 emission factor of process vent flow from mine water. This data element is required.
CC068CCScreen ErrorThe CO2 emission factor of process vent flow from mine water. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC069CCData CompletenessThe CO2 emission mass emission rate during the performance test. This data element is required.
CC070CCScreen ErrorThe CO2 emission mass emission rate during the performance test. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CC123CCData CompletenessYou have added Subpart CC, but have not yet added a manufacturing line.
CEMSML-1CCData CompletenessMonitoring Location (CML) process units. You have added one or more units monitored by CEMS, but have not yet added a CEMS Monitoring Location (CML).
CEMSML-2CCData CompletenessCEMS Monitoring Location (CML) process units. You have indicated that this unit is monitored by CEMS, but you have not yet associated it with any CEMS Monitoring Locations (CMLs). From the Subpart Overview page, click on the CML Name/Identifier to which this unit exhausts (or use the "ADD a CEMS Monitoring Location" link to create a new one). On the bottom of Add/Edit CEMS Monitoring Location page, use the "ADD/REMOVE a process unit that exhausts to this CEMS Monitoring Location" link to select this unit.
CML-001CCScreen ErrorCEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL.
CML-002CCScreen ErrorConfiguration type. This data element is required. Please enter the required data or click CANCEL.
CML-007CCData CompletenessTotal carbon dioxide (CO2) emissions measured by the CEMS. This data element is required.
CML-007XCCScreen ErrorTotal carbon dioxide (CO2) emissions measured by the CEMS (or applicable Part 75 methodology). This data element must be greater than or equal to biogenic carbon dioxide emissions.
CML-012CCScreen ErrorYou have entered a calculation methodology start date that is later than the calculation methodology end date. You must correct this before continuing.
CML-013CCScreen ErrorCalculation methodology start date. This data element is required. Please enter the required data or click CANCEL.
CML-014CCScreen ErrorCalculation methodology end date. This data element is required. Please enter the required data or click CANCEL.
CML-016CCScreen ErrorCarbon dioxide emissions in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-018CCScreen ErrorCarbon dioxide emissions in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-020CCScreen ErrorCarbon dioxide emissions in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-022CCScreen ErrorCarbon dioxide emissions in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-027aCCData CompletenessFraction of nitrous oxide emissions from CML. This data element is required.
CML-034CCScreen ErrorTotal number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-035CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-036CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-037CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-038CCScreen ErrorTotal number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-039CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-040CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-041CCScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-043CCData CompletenessThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This data element is required.
CML-046CCData CompletenessCEMS Monitoring Location process units. You did not select any process unit(s) for this CML.
CML-047aCCData CompletenessFraction of methane emissions from CML. This data element is required.
CML-051CCData CompletenessTotal Non-biogenic carbon dioxide emissions. This data element is required.
CML-052CCData CompletenessTotal Biogenic carbon dioxide emissions. This data element is required.
CML-053CCData CompletenessTotal methane (CH4) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-054CCData CompletenessTotal nitrous oxide (N2O) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-055CCData CompletenessTotal carbon dioxide (CO2) emissions measured by the CEMS. This data element is required.
CML-056CCScreen ErrorTotal annual CO2 mass emissions (biogenic and non-biogenic) measured by the CEMS. This data element must be greater than or equal to biogenic carbon dioxide emissions.
CML-057CCData CompletenessTotal number of source operating hours in the reporting year. This data element is required.
CML-058CCData CompletenessThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This data element is required.
CML-059CCScreen ErrorYou have entered a calculation methodology start date that is later than the calculation methodology end date. Please revise and make sure the Start Date is less than the End Date.
CML-060CCScreen ErrorCalculation methodology start date. This data element is required. Please enter the required data or click CANCEL.
CML-061CCScreen ErrorConfiguration type. This data element is required. Please enter the required data or click CANCEL.
CML-062CCScreen ErrorCalculation methodology end date. This data element is required. Please enter the required data or click CANCEL.
CML-063CCData CompletenessCarbon dioxide emissions measured in Quarter 1. This data element is required.
CML-064CCScreen ErrorCarbon dioxide emissions measured in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-065CCData CompletenessCarbon dioxide emissions measured in Quarter 2. This data element is required.
CML-066CCScreen ErrorCarbon dioxide emissions measured in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-067CCData CompletenessCarbon dioxide emissions measured in Quarter 3. This data element is required.
CML-068CCScreen ErrorCarbon dioxide emissions measured in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-069CCData CompletenessCarbon dioxide emissions measured in Quarter 4. This data element is required.
CML-070CCScreen ErrorCarbon dioxide emissions measured in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-071CCScreen ErrorCEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL.
CML-072CCData CompletenessType(s) of fuel combusted in the unit(s) monitored by the CEMS. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-073CCScreen ErrorTotal methane (CH4) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL.
CML-074CCScreen ErrorTotal nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL.
CML-075CCScreen ErrorTypes of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL.
CML-076CCScreen ErrorTotal methane (CH4) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL.
CML-077CCScreen ErrorTotal nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL.
CML-078CCScreen ErrorTypes of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL.
CML-082CCData CompletenessCarbon dioxide emissions attributable to combustion. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-083CCScreen ErrorCarbon dioxide emissions attributable to combustion. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported emissions and leave the types of emissions field blank, or click CANCEL.
CML-086CCScreen ErrorThe Calculation Methodology Start Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year.
CML-087CCScreen ErrorThe Calculation Methodology Start Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year.
CML-088CCScreen ErrorThe Calculation Methodology End Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year.
CML-089CCScreen ErrorThe Calculation Methodology End Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year.
IVT-CC001CCScreen ErrorInorganic carbon content in trona input, from the carbon analysis for month [{1}]. This data element is required. Please enter the required data or click CANCEL.
IVT-CC002CCScreen ErrorInorganic carbon content in trona input, from the carbon analysis for month [{1}]. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing.
IVT-CC005CCScreen ErrorMass of trona input in month [{1}]. This data element is required. Please enter the required data or click CANCEL.
IVT-CC006CCScreen ErrorMass of trona input in month [{1}]. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-CC008CCScreen ErrorInorganic carbon content in soda ash output, from the carbon analysis for month [{1}]. This data element is required. Please enter the required data or click CANCEL.
IVT-CC009CCScreen ErrorInorganic carbon content in soda ash output, from the carbon analysis for month [{1}]. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing.
IVT-CC012CCScreen ErrorMass of soda ash output in month [{1}]. This data element is required. Please enter the required data or click CANCEL.
IVT-CC013CCScreen ErrorMass of soda ash output in month [{1}]. You must enter a value that is greater than or equal to zero. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-CC015CCScreen ErrorEnter Own Result for Result (ECO2). This data element is required if you select Enter/Report Alternate Result.
IVT-CC016CCScreen ErrorEnter Own Result for Result (ECO2). You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-CC018CCScreen ErrorEnter Own Result for Result (ECO2). This data element is required if you select Enter/Report Alternate Result.
IVT-CC019CCScreen ErrorEnter Own Result for Result (ECO2). You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-CC100CCData CompletenessYou have not yet added any equation inputs data for the annual CO2 process emissions for this manufacturing line. Please use the Inputs Verifier Tool to enter equation inputs for this manufacturing line and calculate a result for this manufacturing line.
IVT-CC101CCData CompletenessYou have not yet added any equation inputs data for the annual CO2 process emissions for this manufacturing line. Please use the Inputs Verifier Tool to enter equation inputs for this manufacturing line and calculate a result for this manufacturing line.


 Back

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2023.R.01)