Critical Validation Checks for Subpart BB

Certain validation checks which are considered critical errors must be corrected before you can successfully generate your submission package or upload your XML-based submission. These checks are presented to the reporter when they attempt to generate or regenerate their submission or after they attempt to upload an XML-based submission. These checks are signified with a stop sign in your validation report.   The table below provides a list of critical errors.   Additional technical information that may assist XML uploaders is also available at XML Upload Critical Errors.  If you feel that you have triggered one of these checks in error, or if there’s a reason why your report should be submitted despite the check being triggered, you may submit a request to the e-GGRT Help Desk at GHGReporting@epa.gov.

CODESUBPARTTYPEMESSAGE_TEXT
BB001BBData CompletenessAnnual carbon dioxide mass emissions. This data element is required.
BB002BBScreen ErrorAnnual carbon dioxide mass emissions. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB004BBData CompletenessAnnual methane mass emissions. This data element is required.
BB005BBScreen ErrorAnnual methane mass emissions. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB007BBScreen ErrorFile size is greater than the maximum of 2 MB.
BB008BBData CompletenessYou have not uploaded a reporting form file.
BB009BBData CompletenessAnnual production of silicon carbide. This data element is required.
BB010BBScreen ErrorAnnual production of silicon carbide. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB013BBData CompletenessAnnual production capacity of silicon carbide. This data element is required.
BB014BBScreen ErrorAnnual production capacity of silicon carbide. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB017BBData CompletenessAnnual consumption of petroleum coke. This data element is required.
BB018BBScreen ErrorAnnual consumption of petroleum coke. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB019BBData CompletenessIndicator of whether the carbon content of petroleum coke is based on reports from the supplier or through self measurement using applicable ASTM standard method. This data element is required.
BB020BBData CompletenessMeasured carbon content of petroleum coke as determined for QA/QC of supplier data. This data is required.
BB021BBScreen ErrorMeasured carbon content of petroleum coke as determined for QA/QC of supplier data. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing or click CANCEL.
BB023BBData CompletenessNumber of months that missing data procedures were followed to determine the carbon content of petroleum coke. This data element is required.
BB024BBScreen ErrorNumber of months that missing data procedures were followed to determine the carbon content of petroleum coke. You must enter a value that is greater than or equal to zero and less than or equal to 12. You must correct the current value before continuing or click CANCEL.
BB025BBData CompletenessNumber of months that missing data procedures were followed to determine the monthly petroleum coke consumption. This data element is required.
BB026BBScreen ErrorNumber of months that missing data procedures were followed to determine the monthly petroleum coke consumption. You must enter a value that is greater than or equal to zero and less than or equal to 12. You must correct the current value before continuing or click CANCEL.
BB027BBData CompletenessAnnual nitrous oxide mass emissions. This data element is required.
BB028BBScreen ErrorAnnual nitrous oxide mass emissions. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB029BBData CompletenessAnnual methane mass emissions. This data element is required.
BB030BBScreen ErrorAnnual methane mass emissions. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing or click CANCEL.
BB100BBData CompletenessYou have not selected the Subpart BB calculation methodology for your facility.
CEMSML-1BBData CompletenessMonitoring Location (CML) process units. You have added one or more units monitored by CEMS, but have not yet added a CEMS Monitoring Location (CML).
CEMSML-2BBData CompletenessCEMS Monitoring Location (CML) process units. You have indicated that this unit is monitored by CEMS, but you have not yet associated it with any CEMS Monitoring Locations (CMLs). From the Subpart Overview page, click on the CML Name/Identifier to which this unit exhausts (or use the "ADD a CEMS Monitoring Location" link to create a new one). On the bottom of Add/Edit CEMS Monitoring Location page, use the "ADD/REMOVE a process unit that exhausts to this CEMS Monitoring Location" link to select this unit.
CML-001BBScreen ErrorCEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL.
CML-002BBScreen ErrorConfiguration type. This data element is required. Please enter the required data or click CANCEL.
CML-007BBData CompletenessTotal carbon dioxide (CO2) emissions measured by the CEMS. This data element is required.
CML-007XBBScreen ErrorTotal carbon dioxide (CO2) emissions measured by the CEMS (or applicable Part 75 methodology). This data element must be greater than or equal to biogenic carbon dioxide emissions.
CML-012BBScreen ErrorYou have entered a calculation methodology start date that is later than the calculation methodology end date. You must correct this before continuing.
CML-013BBScreen ErrorCalculation methodology start date. This data element is required. Please enter the required data or click CANCEL.
CML-014BBScreen ErrorCalculation methodology end date. This data element is required. Please enter the required data or click CANCEL.
CML-016BBScreen ErrorCarbon dioxide emissions in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-018BBScreen ErrorCarbon dioxide emissions in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-020BBScreen ErrorCarbon dioxide emissions in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-022BBScreen ErrorCarbon dioxide emissions in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-027aBBData CompletenessFraction of nitrous oxide emissions from CML. This data element is required.
CML-034BBScreen ErrorTotal number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-035BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-036BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-037BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-038BBScreen ErrorTotal number of source operating hours in the reporting year. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-039BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-040BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-041BBScreen ErrorThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas moisture content. This value should be reported as a number of hours in the reporting year, and should be within the range of 0 to 8784 (hours). The value you provided is outside that range. You must correct the current value before continuing.
CML-043BBData CompletenessThe total operating hours in which a substitute data value was used in the emissions calculations for stack gas flow rate. This data element is required.
CML-046BBData CompletenessCEMS Monitoring Location process units. You did not select any process unit(s) for this CML.
CML-047aBBData CompletenessFraction of methane emissions from CML. This data element is required.
CML-051BBData CompletenessTotal Non-biogenic carbon dioxide emissions. This data element is required.
CML-052BBData CompletenessTotal Biogenic carbon dioxide emissions. This data element is required.
CML-053BBData CompletenessTotal methane (CH4) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-054BBData CompletenessTotal nitrous oxide (N2O) emissions. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-055BBData CompletenessTotal carbon dioxide (CO2) emissions measured by the CEMS. This data element is required.
CML-056BBScreen ErrorTotal annual CO2 mass emissions (biogenic and non-biogenic) measured by the CEMS. This data element must be greater than or equal to biogenic carbon dioxide emissions.
CML-057BBData CompletenessTotal number of source operating hours in the reporting year. This data element is required.
CML-058BBData CompletenessThe total operating hours in which a substitute data value was used in the emissions calculations for carbon dioxide (CO2) concentration. This data element is required.
CML-059BBScreen ErrorYou have entered a calculation methodology start date that is later than the calculation methodology end date. Please revise and make sure the Start Date is less than the End Date.
CML-060BBScreen ErrorCalculation methodology start date. This data element is required. Please enter the required data or click CANCEL.
CML-061BBScreen ErrorConfiguration type. This data element is required. Please enter the required data or click CANCEL.
CML-062BBScreen ErrorCalculation methodology end date. This data element is required. Please enter the required data or click CANCEL.
CML-063BBData CompletenessCarbon dioxide emissions measured in Quarter 1. This data element is required.
CML-064BBScreen ErrorCarbon dioxide emissions measured in Quarter 1. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-065BBData CompletenessCarbon dioxide emissions measured in Quarter 2. This data element is required.
CML-066BBScreen ErrorCarbon dioxide emissions measured in Quarter 2. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-067BBData CompletenessCarbon dioxide emissions measured in Quarter 3. This data element is required.
CML-068BBScreen ErrorCarbon dioxide emissions measured in Quarter 3. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-069BBData CompletenessCarbon dioxide emissions measured in Quarter 4. This data element is required.
CML-070BBScreen ErrorCarbon dioxide emissions measured in Quarter 4. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
CML-071BBScreen ErrorCEMS Monitoring Location Name/ID. This data element is required. Please enter the required data or click CANCEL.
CML-072BBData CompletenessType(s) of fuel combusted in the unit(s) monitored by the CEMS. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-073BBScreen ErrorTotal methane (CH4) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL.
CML-074BBScreen ErrorTotal nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL.
CML-075BBScreen ErrorTypes of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the "Process/stationary combustion units share common stack" configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL.
CML-076BBScreen ErrorTotal methane (CH4) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total methane emissions field blank, or click CANCEL.
CML-077BBScreen ErrorTotal nitrous oxide (N2O) emissions. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the value and leave the total nitrous oxide emissions field blank, or click CANCEL.
CML-078BBScreen ErrorTypes of fuel combusted in the unit(s) monitored by the CEMS. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported fuel(s) and leave the types of fuel field blank, or click CANCEL.
CML-082BBData CompletenessCarbon dioxide emissions attributable to combustion. This data element is required for CMLs using the \'Process/stationary combustion units share common stack\' configuration type.
CML-083BBScreen ErrorCarbon dioxide emissions attributable to combustion. This data element is only required to be reported for CMLs using the \'Process/stationary combustion units share common stack\' configuration type. Please remove the reported emissions and leave the types of emissions field blank, or click CANCEL.
CML-086BBScreen ErrorThe Calculation Methodology Start Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year.
CML-087BBScreen ErrorThe Calculation Methodology Start Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the start date is within the current reporting year.
CML-088BBScreen ErrorThe Calculation Methodology End Date is earlier than the first applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year.
CML-089BBScreen ErrorThe Calculation Methodology End Date is later than the last applicable day of reporting your Tier 4 Methodology. Please revise and make sure the End Date is within the current reporting year.
IVT-BB001BBScreen ErrorCarbon content factor for petroleum coke consumed in month [{1}] from the supplier or as measured by the applicable method. This data element is required. Please enter the required data or click CANCEL.
IVT-BB002BBScreen ErrorCarbon content factor for petroleum coke consumed in month [{1}] from the supplier or as measured by the applicable method. You must enter a value that is greater than or equal to zero and less than or equal to one. You must correct the current value before continuing.
IVT-BB007BBScreen ErrorPetroleum coke consumption in month [{1}]. This data element is required. Please enter the required data or click CANCEL.
IVT-BB008BBScreen ErrorPetroleum coke consumption in month [{1}]. You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-BB009BBScreen ErrorEnter Own Result for Result (ECO2). This data element is required if you select Enter/Report Alternate Result.
IVT-BB010BBScreen ErrorEnter Own Result for Result (ECO2). You must enter a value that is greater than or equal to zero. You must correct the current value before continuing.
IVT-BB100BBData CompletenessYou have not yet added any equation inputs data for the CO2 emission factor in month. Please use the Inputs Verifier Tool to enter equation inputs for each carbon content factor for petroleum coke consumed in a month from the supplier or as measured by the applicable method and calculate a result for this silicon carbide facility.
IVT-BB101BBData CompletenessYou have not yet added any equation inputs data for the annual CO2 emissions from the silicon carbide production facility. Please use the Inputs Verifier Tool to enter equation inputs for the petroleum coke consumption in month and calculate a result for this silicon carbide facility.


 Back