Q649. Do we include the quantity of SF6 contained in hermetically sealed equipment when determining applicability under subpart DD?

 

A649. No, hermetically sealed-pressure equipment is excluded when determining if you exceed the reporting threshold of 17,820 pounds according to 98.301(a). However, the calculation parameters specified in equation DD-1 do include the quantity of SF6 contained in hermetically sealed equipment, so information on hermitically sealed equipment is included in the reporting requirements for subpart DD.

 

Unknown macro: {show-to} Footer / References Bar which is Visible to the public

Updated on

Unknown macro: {show-to}

Source: EPA (David Jacobson, 3/20/2012)

Approval / Publishing History: Version 1, minor revisions per S. Bogle 3/1/18

Expiration: none

Relevant Subpart: DD

History Panel For Internal Use - Not Visible to the Public