Q100. When does moisture content need to be corrected for in Equation HH-4?

A100. If CH4 concentration and flow are both measured on a wet basis or both measured on a dry basis, then no moisture correction is needed. If one is measured on a wet basis and the other on a dry basis, then correction is needed.


Unknown macro: {show-to}
Unknown macro: {center} Footer / References Bar which is Visible to the public

Updated on

Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ, revised by R. Schmeltz, 2/11/2013

Approval / Publishing History: Version 2, approved by L. Grogan-McCulloch, 2/13/2013

Expiration: none

Relevant Subparts: Subpart HH

Unknown macro: {center} History Panel For Internal Use - Not Visible to the Public