Q76. For a group of units that combusts only pipeline quality natural gas, may a shared fuel flow meter on a common pipe or gas supplier billing meter data be used to determine the CO2 mass emissions for the group of units?

 

A76. Yes. Fuel flow metering using a calibrated fuel flow meter on a common pipe or gas supplier billing meter data may be used to determine CO2 mass emissions for a group of units sharing a common +gaseous or liquid +fuel supply (See §§98.36(c)(3) and 98.34(b)(1)(iii).) 