Q120. Is weekly monitoring of both gas flow and methane concentration allowed?

A120. No, landfill gas flow must be monitored continuously.  Methane concentration can be monitored monthly if continuous monitoring is not already in place.  Please note that the methane concentration in the landfill gas is required to be measured once each calendar month.  If only one measurement is made each calendar month, there must be at least fourteen days between measurements.


Show If
special@authenticated
Footer / References Bar which is Visible to the public
Wiki Markup
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}
Panel

Updated on

Page info
infoTypeModified modified- datemodified-date
typeFlat
dateformatdd/MM/YY HH:mm

Show If
special@authenticated
Info

Source: This question and answer was derived from a Legacy FAQ. Revised by Rachel Schmeltz,