Q82.
...
For
...
a
...
non-Acid
...
Rain
...
combustion
...
turbine
...
rated
...
over
...
250
...
mmBtu
...
per
...
hour
...
that
...
only
...
burns
...
diesel
...
oil
...
and
...
pipeline
...
natural
...
gas,
...
is
...
it
...
acceptable
...
to
...
use
...
Tier
...
2
...
to
...
calculate
...
CO2
...
emissions?
...
Is
...
the
...
use
...
of
...
Tier
...
2
...
also
...
allowed
...
if
...
the
...
turbine
...
combusts
...
only
...
one
...
of
...
these
...
fuels?
...
A82. Yes, to both questions. Tier 2 may be used in a unit with a maximum rated heat input capacity greater than 250 mmBtu/hr for the combustion of pipeline natural gas and/or distillate fuel oil. (See §98.33(b)(2)(ii) and the definition of “distillate fuel oil” in §98.6.)