Q82. For a non-Acid Rain combustion turbine rated over 250 mmBtu per hour that only burns diesel oil and pipeline natural gas, is it acceptable to use Tier 2 to calculate CO2 emissions? Is the use of Tier 2 also allowed if the turbine combusts only one of these fuels?

Yes, to both questions. Tier 2 may be used in a unit with a maximum rated heat input capacity greater than 250 mmBtu/hr for the combustion of pipeline natural gas and/or distillate fuel oil. (See §98.33(b)(2)(ii) and the definition of “distillate fuel oil” in §98.6.)

Unknown macro: {show-to}
Unknown macro: {center} Footer / References Bar which is Visible to the public

Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration : None

Relevant Subparts: Subpart C

Unknown macro: {center} History Panel For Internal Use - Not Visible to the Public

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)