Q522. Are LNG storage sites located adjacent to subpart D facilities under “common control” required to report emissions under the subpart D “facility” or should the LDC report the emissions under subpart W?
A521. Based on the information provided, the questioner would report as a single facility under 40 CFR 98. The single facility would be required to report emissions separately for subparts C, D and W in the EPA electronic greenhouse gas reporting system (eGGRT). In regard to specific sources, subpart W requires the reporting of process and emissions from any source listed in 98.232(g) sent to a flare from LNG storage facilities, as defined in 40 CFR 98.230, under subpart W according to the calculation procedures outlined in 98.233. Additional applicable emissions are to be reported under subpart D according to the methods described in subpart D. Finally, stationary combustion emissions are to be reported under subpart C.
Wiki Markup |
---|
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to} |
Panel |
---|
Updated on Page info |
---|
| modified-date |
---|
| modified-date |
---|
dateformat | dd/MM/YY HH:mm |
---|
|
|
Wiki Markup |
---|
{show-to:group=confluence-Users}
{info}
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, [http://www.epa.gov/ghgreporting/documents/pdf/2011/documents/Subpart-W-additional-faq.pdf].