Q522. Are LNG storage sites located adjacent to subpart D facilities under “common control” required to report emissions under the subpart D “facility” or should the LDC report the emissions under subpart W?

A522. Based on the information provided, the questioner would report as a single facility under 40 CFR 98.  The single facility would be required to report emissions separately for subparts C, D and W in the EPA electronic greenhouse gas reporting system (eGGRT).  In regard to specific sources, subpart W requires the reporting of process and emissions from any source listed in 98.232(g) sent to a flare from LNG storage facilities, as defined in 40 CFR 98.230, under subpart W according to the calculation procedures outlined in 98.233.  Additional applicable emissions are to be reported under subpart D according to the methods described in subpart D.  Finally, stationary combustion emissions are to be reported under subpart C.


Updated on 

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)