...
Q785.
...
When
...
can
...
I
...
use
...
a
...
collection
...
efficiency
...
(CE)
...
of
...
75%
...
from
...
Table
...
HH-3?
A785. Under section 98.343(c) of the rule, the collection efficiency (CE) estimated at the landfill is calculated using an area-weighted average (see Table HH-3 of this subpart) that accounts for system coverage, operation, and cover system materials. If area by soil cover type information is not available, you may use default value of 0.75 (CE4 in table HH-3 of this subpart) for all areas under active influence of the gas collection system. Please note that landfills with Area Type A2 as defined in Table HH-3, i.e., “Area without active gas collection, regardless of cover type,” cannot simply use the default of 0.75 for CE in Equations HH-7 and HH-8.
...
Wiki Markup |
---|
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to} |
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
Updated on
|
Wiki Markup |
---|
{show-to:group=confluence-Users} {info} Source: Rachel Schmeltz, 2/6/2014 (HH_RY2013_FAQs_v2_2-6-2014.docx) Approval / Publishing History: Version 1 Expiration: none Relevant Subparts: Subpart HH {info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to} |