Subpart K consists of facilities that use pyrometallurgical techniques to produce any of the following metals: ferrochromium, ferromanganese, ferromolybdenum, ferronickel, ferrosilicon, ferrotitanium, ferrotungsten, ferrovanadium, silicomanganese, or silicon metal.

This page provides an overview of subtopics that are central to Subpart K reporting. This information is entered from the e-GGRT Subpart K Overview web form shown below. Each topic represents a key web form(s) you where you need to enter information:

Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak:id=PNG1}
Click image to expand
Image Removed

Wiki Markup
{cloak:id=PNG1|cloak.toggle.type=none|cloak.toggle.zone=true}
Panel

Image Removed

Composition Setup

Toggle Cloak
idPNG1
Click this link to expand
Image Added

Cloak
cloak.toggle.zonetrue
idPNG1
cloak.toggle.typenone
 
Wiki Markup
{cloak}

The end of the page provides links you can use for more detailed information and instructions on entering required information related to each of these topics.

Summary Information for this Facility
Anchor
Summary Information for this FacilitySubpart K Summary Information for this Facility

...

...

Subpart K Summary Information for this Facility

...

Subpart K Summary Information for this Facility

Anchor
Subpart K EAF Information
Subpart K EAF Information

Back to Top

Subpart K Furnace Informationanchor

The required electric arc furnace (EAF) information and the forms associated with required EAF information is entered into e-GGRT are different for electric arc furnaces (EAFs) that are monitored by a Continuous Emissions Monitoring System (CEMS) and for EAFs that are NOT monitored by a CEMS.

As a result, separate help content has been created in this subpart for entering EAF information for EAFs monitored by a CEMS and for EAFs NOT monitored by a CEMS.

For each EAF NOT monitored by a CEMS at your facility, Subpart K requires you to report the following information:

  • A unique name or identifier, plus optional description for this EAF (see also About Unique Unit Names)
  • The following data for each input and output associated with the EAF:
    • A unique name or identifier
    • The general type of input or output

For each EAF monitored by a CEMS at your facility, Subpart K requires you to report a unique name or identifier, plus optional description for the EAF (see also About Unique Unit Names).

Anchor
Subpart K Emissions Information
Subpart K Emissions Information

Back to Top

Subpart K Emissions Information Anchor

The required emissions information, and the manner by which required emissions information it is entered into e-GGRT, is different for EAFs that are monitored by a Continuous Emissions Monitoring System ( CEMS ) and for EAFs that are NOT monitored by a CEMS.

As a result, separate help content has been created in this subpart for entering emissions information for EAFs monitored by a CEMS and for EAFs NOT monitored by a CEMS.

For each EAF that is NOT monitored by a CEMS at your facility, Subpart K requires the following emissions information:

  • The annual CO2 process emissions (the output of Equation K-1, in metric tons)  (for RY2014 and later years enter Eq. K-1 inputs using IVT to calculate CO2 process emissions)
  • For each EAF used for the production of a ferroalloy listed in Table K-1, the annual CH4 process emissions (the output of Equation K-3, in metric tons) (for RY2014 and later years enter Eq. K-3 inputs using IVT to calculate CH4 process emissions)*
  • For each Input and Output assigned to an electric arc furnace, Subpart K collects the following data:
    • The method used to determine carbon content (Provided by supplier, ASTM E1941-04, ASTM D5373-08, or ASTM C25-06)
    • An indication if a missing data procedure was used or analysis was repeated to determine carbon content
    • The procedure used to develop substitute data for monthly mass, if applicable (Purchase records or Other)
    • The number of months that missing data procedures were followed to determine monthly mass

*Note, reporting of CH4 process emissions is only required for ferroalloy types listed in Table K-1. If you do not produce a ferroalloy type listed in this table, enter “0” for your emissions.

For each CEMS Monitoring LocationWhere EAFs are monitored by a CEMS, provide the following information for each CEMS Monitoring Location (CML):

  • A unique unit name or identifier for the CML (see also About Unique Unit Names)
  • An optional description or label for the CML
  • The configuration of processes or process units that are monitored by the CML:
    • Single process or process unit that exhausts to a dedicated stack
    • Multiple processes or process units that share a common stack
    • Process or process unit that shares a common stack with one or more stationary fuel combustion units
  • The name of each fuel combusted in the unit(s) monitored by the CEMS
  • The Tier 4/CEMS methodology start and end dates
  • The cumulative total of hourly CO2 mass emissions for each quarter of the reporting year (metric tons) (Do not cumulate emissions data between quarters)
  • The total annual CO2 mass emissions measured by the CEMS (metric tons)
  • An indication of whether emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS
  • The total annual biogenic CO2 emissions from the combustion of all biomass fuels combined (metric tons) (if not applicable, enter '0')
  • The total annual non-biogenic CO2 emissions which includes fossil fuel, sorbent, and process CO2 emissions (metric tons)
  • The total annual CH4 and N2O emissions associated with the combustion of all Table C-2 fuels combusted in all processes/process units monitored by the CEMS derived from application of Equation C-10 (metric tons) (if there are no combustion emissions in this CML, please enter '0')
  • The total number of source operating hours in the reporting year
  • The total operating hours in which a substitute data value was used in the emissions calculations for the CO2 concentration parameter
  • The total operating hours in which a substitute data value was used in the emissions calculations for the stack gas flow rate parameter
  • If moisture correction is required and a continuous moisture monitor is used, the total operating hours in which a substitute data value was used in the emissions calculations for the stack gas moisture content parameter
  • An indication of the process units monitored by the CML
  • For each EAF listed that is monitored by CEMS, enter the annual production for each Ferroalloy Product. If the specific electric arc furnace did not produce any of a given ferroalloy product, simply un-check the box, and the numeric entry box will disappear.

    List of Ferroalloy Products

    • Ferrochromium
    • Ferromanganese
    • Ferromolybdenum
    • Ferronickel
    • Ferrosilicon
    • Ferrotitanium
    • Ferrotungsten
    • Ferrovanadium
    • Silicomanganese
    • Silicon metal

Anchor
Subpart K Validation Report
Subpart K Validation Report

Back to Top

Subpart K Validation Reportanchor

Excerpt Include
Subpart Validation Report
Subpart Validation Report
nopaneltrue

...

#Back Back to Top

See Also

Screen Errors
Using e-GGRT to Prepare Your Subpart K Report
Subpart K Summary Information for this Facility
Using e-GGRT to Prepare Your Subpart K Furnace Information for Furnaces NOT Monitored by CEMSReport
Subpart K Furnace Information for Furnaces Monitored by CEMS
Subpart K Emissions Information for Furnaces NOT Monitored by CEMS
Subpart K Emissions Information for Furnaces Monitored by CEMS
Subpart Validation Report

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2023.R.01)