{longname} Q133. Can I use more than 1 Tier Method for my facility? {longname} |
A133.
...
Yes.
...
The
...
tier
...
methodology
...
applies
...
to
...
each
...
unit
...
and
...
to
...
each
...
fuel
...
combusted
...
in
...
a
...
unit.
...
Therefore,
...
you
...
can
...
use
...
different
...
tiers
...
for
...
different
...
units
...
and
...
different
...
tiers
...
for
...
different
...
fuels
...
in
...
a
...
co-fired
...
unit
...
(providing
...
that
...
an
...
allowable
...
tier
...
method
...
is
...
used
...
in
...
each
...
situation).
...
The
...
exception
...
is
...
if
...
you
...
use
...
common
...
pipe
...
provisions
...
for
...
multiple
...
units.
...
In
...
this
...
case,
...
you
...
must
...
use
...
the
...
highest
...
tier
...
method
...
that
...
applies
...
to
...
any
...
unit
...
within
...
the
...
aggregated
...
group
...
for
...
which
...
you
...
use
...
the
...
common
...
pipe
...
provision.
...
(See
...
§98.33(b)(6)
...
and
...
§98.36(c)(3).)
...