Q100. When does moisture content need to be corrected for in Equation HH-4?
A100. If CH4 concentration and flow are both measured on a wet basis or both measured on a dry basis, then no moisture correction is needed. If one is measured on a wet basis and the other on a dry basis, then correction is needed. Wiki Markup |