Q304.
...
When
...
asked
...
in
...
e-GGRT
...
if
...
a
...
unit
...
has
...
a
...
CEMS,
...
is
...
it
...
specifically
...
referring
...
to
...
a
...
CO2
...
CEMS?
...
A304. The question is referring to whether CO2 emissions for a given process unit are calculated according to the Tier 4 calculation methodology specified in section 98.33(a)(4). The question is not asking if a Continuous Emission Monitoring System or gas monitor of any kind is being use to monitor pollutant emissions for a given unit.