{longname}
Q543. This question relates to subpart W, Acid Gas Removal Vents, using Calculation Methodology 3 (98.233.d). In 98.233.d.8 are we allowed to assume that volume fraction of CO2 content in natural gas out of the AGR unit is zero? This will result in a conservative estimate of AGR vent emissions.
{longname}

A543.

...

No.

...

§98.233(d)(8)

...

does

...

not

...

instruct

...

reporters

...

to

...

assume

...

a

...

volumetric

...

fraction

...

of

...

zero

...

for

...

Vol

...

0.

...

Reporters

...

must

...

use

...

one

...

of

...

the

...

methods

...

specified

...

in

...

§98.233(d)(8)

...

to

...

determine

...

the

...

CO

...

2 content

...

of

...

the

...

natural

...

gas

...

exiting

...

the

...

AGR

...

unit

...

(Vol

...

0).

Wiki Markup
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}

{
Panel
}

Updated

on

on

Wiki Markup
{page-info:modified-date|dateformat=dd/MM/YY HH:mm}

{panel}

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, [http://www.epa.gov/climatechange/emissions/downloads11/documents/Subpart-W-additional-faq.pdf].  Updated to clarify subscripts

Approval / Publishing History: Version 2, approved by M. Eaddy, 6/4/2012

Expiration : none

Relevant Subpart: W, Acid Gas Removal
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to}

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)