longname |
---|
Wiki Markup |
{longname} Q87. What Tier, if any, must be used for a fuel not listed in Table C-1 that is less than 10% of the heat input of a combustion unit? {longname} |
If
...
the
...
unit
...
is
...
less
...
than
...
or
...
equal
...
to
...
250
...
mmBtu/hr,
...
GHG
...
emissions
...
reporting
...
is
...
not
...
required
...
if
...
the
...
fuel
...
or
...
the
...
fuel
...
constituents
...
are
...
not
...
listed
...
in
...
Table
...
C-1.
...
However,
...
if
...
the
...
unit
...
is
...
greater
...
than
...
250
...
mmBtu/hr,
...
CO2
...
emissions
...
reporting
...
for
...
a
...
fuel
...
not
...
listed
...
in
...
Table
...
C-1
...
is
...
required,
...
using
...
Tier
...
3,
...
if:
...
(1)
...
combustion
...
of
...
the
...
fuel
...
accounts
...
for
...
10%
...
or
...
more
...
of
...
the
...
combustion
...
unit’s annual
...
heat
...
input;
...
and
...
(2)
...
the
...
unit
...
is
...
not
...
required
...
to
...
use
...
Tier
...
4.
...
This
...
response
...
applies
...
only
...
to
...
units
...
that
...
calculate
...
CO2
...
emissions
...
in
...
accordance
...
with
...
Subpart
...
C.
...
(See
...
§98.33(b)(3)(iii).)
...
Wiki Markup |
---|
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to} |
Panel | |||
---|---|---|---|
} Updated onon
|
Wiki Markup |
---|
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ
Approval / Publishing History: Version 1
Expiration : none
Relevant Subparts: Subpart C
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to} |