Subpart Y Flares Unit Information

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Comment: Migrated to Confluence 4.0

Anchor
Back to Top
Back to Top

This topic provides a step-by-step description of how to enter Subpart Y Flares unit information about this facility.

Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG1}
Click image to expand

Wiki Markup
{cloak:id=PNG1|
Cloak
cloak.toggle.zonetrue
idPNG1
cloak.toggle.type
none
=none|cloak.toggle.zone=true}
Panel

Image Added

Wiki Markup
{cloak}

Step 1. Step 1. Adding or Updating Flares Unit Information

...

To delete an existing Flare Unit, click on the delete icon, which is the last column in the FLARES UNITS EMISSIONS SUMMARY table.

Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG2}
Click image to expand

cloaktrue
Wiki Markup
{cloak:id=PNG2|cloak
Cloak
.toggle.type=none|cloak.toggle.zone=true}
Panel

Image Added

none
Wiki Markup
{cloak}
idPNG2
cloak.toggle.type

Excerpt

Subpart Y collects the following data about your flare unit:

  • A unique name or identifier, plus optional description for this flare unit (see also About Unique Unit Names)
  • Type of flare:
    • Steam assisted
    • Air assisted
    • Unassisted
    • Other (specify)
  • Flare service type:
    • General facility flare
    • Unit flare
    • Emergency only flare
    • Back-up flare
    • Other (specify)
  • Method used to calculate the CO2 emissions:
    • 98.253(b)(1)(ii)(A) – Equation Y-1a Gas Composition Monitored (Equation Y-1a or Y-1b must be used if you have a continuous gas composition monitor on the flare or if you measure it at least weekly)
    • 98.253(b)(1)(ii)(A) – Equation Y-1b Gas Composition Monitored (Equation Y-1a or Y-1b must be used if you have a continuous gas composition monitor on the flare or if you measure it at least weekly)
    • 98.253(b)(1)(ii)(B) – Equation Y-2 Heat Content Monitored (Equation Y-2 must be used if you have a continuous higher heating value monitor or measure it at least weekly and the heating value monitor or measurement is not based on compositional analyses; if compositional analyses are used, you must use Equation Y-1a or Y-1b)
    • 98.253(b)(1)(iii) – Equation Y-3 Start-up, Shutdown, Malfunction (Equation Y-3 must be used if you do not measure gas composition or heating value at least weekly.)

...

To add or update Subpart Y flare emissions information, locate the FLARES UNITS EMISSION SUMMARY table on the Subpart Y Overview page, and click OPEN.

Wiki Markup
{composition-setup
}{composition-setup}

Wiki Markup
{toggle-cloak:id=PNG47}
Toggle CloakidPNG47
Click image to expand

true
Wiki Markup
Cloak
{cloak:id=PNG47|cloak.toggle.type=none|cloak.toggle.zone=true}
Panel

Image Added

none
Wiki Markup
{cloak}
idPNG47
cloak.toggle.type
Step 2b: Equation Summary and Results

...

For each flare at your facility, Subpart Y requires you to enter the following emissions information:

...

  • The annual CO{~}2~ 2 emissions from flare unit operations (the output of Equation Y-1a, Y-1b, Y-2, or Y-3 depending on the calculation method used for this flare, in metric tons) \ [98.256(e)(4)\]
  • Wiki MarkupThe annual CH{~}4~ 4 emissions from flare unit operations (the output of Equation Y-4, in metric tons) \ [98.256(e)(4)\]
  • The basis for the fraction of carbon in the flare gas contributed by methane value:
    • Method 18 at 40 CFR part 60, appendix A-6
    • ASTM D1945-03
    • ASTM D1946-90-Reapproved 2006
    • GPA 2261-00
    • UOP539-97
    • ASTM D2503-92-Reapproved 2007
    • Chromatographic analysis: manufacturer's instructions
    • Engineering calculations
    • Other (specify)
    unmigrated-wiki-markup
  • The annual N{~}2{~}O emissions from flare unit operations (the output of Equation Y-5, in metric tons) \ [98.256(e)(4)\]

The e-GGRT system provides links to optional worksheets that may be used to perform the calculations; use of the spreadsheet is entirely optional and is provided for your assistance. To calculate annual CO2 emissions using the optional spreadsheets, download the calculation spreadsheet by clicking the link titled "Use Y-x spreadsheet to calculate" (where 'x' represents 1a, 1b, 2, or 3 depending on the CO2 calculation method used for this flare). Fill in the spreadsheet using the instructions in the spreadsheet. After completing the spreadsheet, copy the value of CO2 calculated by the spreadsheet to this page in the red box next to "Annual CO2 emission from this flare (metric tons)."

...

For each flare using the Equation Y-1a calculation method, Subpart Y requires you to enter the following supplemental emissions information:

...

  • An indication of whether daily or weekly measurement periods are used \ [98.256(e)(6)\]
  • Wiki MarkupThe annual volume of flare gas combusted (in scf) \ [98.256(e)(6)\]
  • Wiki MarkupThe specific consensus-based standard method number or description of the procedure specified by the flow meter manufacturer \ [98.256(q)\]
  • The number of days during the reporting year missing data procedures were used to determine the volume of flare gas combusted
  • Wiki MarkupThe annual average molecular weight (in kg/kg-mole) \ [98.256(e)(6)\]unmigrated-wiki-markup)]
  • The method used to measure molecular weight \ [98.256(q)\]
    • Method 18 at 40 CFR part 60, appendix A-6
    • ASTM D1945-03
    • ASTM D1946-90 (Reapproved 2006)
    • GPA 2261-00
    • UOP539-97
    • ASTM D2503-92 (Reapproved 2007)
    • Chromatographic analysis: manufacturer's instructions
    • Other (specify)
  • The number of days during the reporting year missing data procedures were used to determine molecular weight
  • Wiki MarkupThe annual average carbon content of the flare gas (kg carbon/kg flare gas) \ [98.256(e)(6)\]unmigrated-wiki-markup
  • The method used to measure carbon content \ [98.256(q)\]
    • Method 18 at 40 CFR part 60, appendix A-6
    • ASTM D1945-03
    • ASTM D1946-90 (Reapproved 2006)
    • GPA 2261-00
    • UOP539-97
    • ASTM D2503-92 (Reapproved 2007)
    • Chromatographic analysis: manufacturer's instructions
    • Other (specify)
  • The number of days during the reporting year missing data procedures were used to determine carbon content
Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG4}
Click image to expand

none
Wiki Markup
Cloak
{cloak:id=PNG4|cloak.toggle.type=none|cloak.toggle.zone
true
idPNG4
cloak.toggle.type
=true}
Panel

Image Added

Wiki Markup
{cloak}

For each flare using the Equation Y-1b calculation method, Subpart Y requires you to enter the following supplemental emissions information:

  • Wiki MarkupAn indication of whether daily or weekly measurement periods are used \ [98.256(e)(7)\]unmigrated-wiki-markup
  • The annual volume of flare gas combusted (in scf) \ [98.256(e)(7)\]unmigrated-wiki-markup
  • The specific consensus-based standard method number or description of the procedure specified by the flow meter manufacturer \ [98.256(q)\]
  • The number of days during the reporting year missing data procedures were used to determine the volume of flare gas combustedunmigrated-wiki-markup
  • The annual average CO{~}2~ 2 concentration (in percent by volume or mole) \ [98.256(e)(7)\]unmigrated-wiki-markup
  • The method used to measure CO{~}2~ concentration \2 concentration [98.256(q)\]
    • Method 18 at 40 CFR part 60, appendix A-6
    • ASTM D1945-03
    • ASTM D1946-90 (Reapproved 2006)
    • GPA 2261-00
    • UOP539-97
    • ASTM D2503-92 (Reapproved 2007)
    • Chromatographic analysis: manufacturer's instructions
    • Other (specify)
  • The number of days during the reporting year missing data procedures were used to determine CO2 concentration
  • For each carbon containing compound other than CO2 in the flare gas stream identified by the facility, and for each flare using Equation Y-1b, the system shall require the facility to identify:
  • Wiki MarkupThe annual average concentration of the compound (in percent by volume or mole) \ [98.256(e)(7)\(i)\] Wiki Markup
  • The method used to measure concentration of the compound \ [98.256(q)\]
    • Method 18 at 40 CFR part 60, appendix A-6
    • ASTM D1945-03
    • ASTM D1946-90 (Reapproved 2006)
    • GPA 2261-00
    • UOP539-97
    • ASTM D2503-92 (Reapproved 2007)
    • Chromatographic analysis: manufacturer's instructions
    • Other (specify)
  • The number of days during the reporting year missing data procedures were used to determine the concentration of the compoundthe compound
Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG5}
Click image to expand

none
Wiki Markup
Cloak
{cloak:id=PNG5|cloak.toggle.type=none|cloak.toggle.zone
true
idPNG5
cloak.toggle.type
=true}
Panel

Image Added

Wiki Markup
{cloak}

To add a non-CO2 carbon-contain compound for the flare, click the "ADD a Compound" link in the CARBON CONTAINING COMPOUNDS (OTHER THAN CO2) IN THE FLARE GAS STREAM section on the Equation Summary and Result page and enter the required information.

When finished entering the required compound information, click SAVE.

Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak:id=PNG6}
Click image to expand
Image Added

unmigrated-inline-wiki-markup
{cloak

...

:id

...

true
Cloak
=PNG6|cloak.toggle.type=none|cloak.toggle.zone=true}
Panel

Image Added

none
Wiki Markup
{cloak}
idPNG6
cloak.toggle.type

For each flare using the Equation Y-2 calculation method, Subpart Y requires you to enter the following supplemental emissions information:

...

  • An indication of whether daily or weekly measurement periods are used \ [98.256(e)(8)\]
  • Wiki MarkupThe annual volume of flare gas combusted (in MMscf) \ [98.256(e)(8)\]
  • Wiki MarkupThe specific consensus-based standard method number or description of the procedure specified by the flow meter manufacturer \ [98.256(q)\]
  • The number of days during the reporting year missing data procedures were used to determine the volume of flare gas combustedunmigrated-wiki-markup
  • The annual average higher heating value of the flare gas (MMBtu/MMscf) \ [98.256(e)(8)\] Wiki Markup
  • The method used to measure higher heating value of the flare gas \ [98.256(q)\]
    • ASTM D4809-06
    • ASTM D240-02 (Reapproved 2007)
    • ASTM D1826-94 (Reapproved 2003)
    • ASTM D3588-98 (Reapproved 2003)
    • ASTM D4891-89 (Reapproved 2006)
    • Chromatographic analysis: manufacturer's instructions
    • Other (specify)
  • The number of days during the reporting year missing data procedures were used to determine the higher heating value of the flare gasunmigrated-wiki-markup
  • An indication of whether the annual volume of flare gas combusted was determined using standard conditions of 68 ºF and 14.7 psia or 60 ºF and 14.7 psia \ [98.256(e)(8)\] Wiki Markup
  • An indication of whether the annual average higher heating value of the flare gas was determined using standard conditions of 68 ºF and 14.7 psia or 60 ºF and 14.7 psia \ [98.256(e)(8)\]]
Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG7}
Click image to expand

none
Wiki Markup
Cloak
{cloak:id=PNG7|cloak.toggle.type=none|cloak.toggle.zone
true
idPNG7
cloak.toggle.type
=true}
Panel

Image Added

Wiki Markup
{cloak}

For each flare using the Equation Y-3 calculation method, Subpart Y requires you to enter the following supplemental emissions information:

  • Wiki MarkupThe total number of start-up, shutdown, or malfunction (SSM) events exceeding 500,000 scf/day \ [98.256(e)(9)\]

...

  • ]
Wiki Markup
{composition-setup}{composition-setup}

Wiki Markup
{toggle-cloak
:id
=PNG8}
Click image to expand

true
Wiki Markup
{cloak:id=PNG8|cloak.toggle.type=none|
Cloak
cloak.toggle.zone=true}
Panel

Image Added

none
Wiki Markup
{cloak}
idPNG8
cloak.toggle.type
Step 2d: Save Your Data

When you have finished entering emission results, click SAVE.

...

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2023.R.01)