Q793. What if my process only has recovery for part of the year?
A793. There may be cases where a lagoon or reactor is only recovering biogas for part of the reporting year, but is operational for the entire reporting year. In this case, the process should be submitted as two separate processes, one with recovery and one without. For the weeks where biogas is not recovered, use equations II-1 or II-2 and II-3 to calculate emissions. For the weeks where biogas is recovered, use equations II-1 or II-2, II-4, II-5 and II-6 to calculate emissions.
Updated on
Source: Rachel Schmeltz, 2/10/2014 (RY2013_Subpart II_FAQs.docx)
Approval / Publishing History: Version 1
Expiration: none
Relevant Subparts: Subpart II