Q95. If a facility has a billing meter for natural gas distributed to the combustion units throughout the facility, and if these combustion units also have their own meters, is there an obligation under the rule to use the individual unit meters and with this the more stringent calibration requirements for each meter?

A95. You would not be required to use the individual unit meters provided you qualify to report under either 40 CFR 98.36(c)(1) (i.e., aggregation of units) or 40 CFR 98.36(c)(3) (i.e., common pipe configuration). However, you must use the highest applicable Tier method to calculate emissions from all of the grouped combustion units.

Unknown macro: {show-to}
Unknown macro: {center}

Footer / References Bar which is Visible to the public

Updated on

Unknown macro: {page-info}
Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration : None

Relevant Subparts: Subpart C

Unknown macro: {center}

History Panel For Internal Use - Not Visible to the Public

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)