Q84. For a unit that is not required to use Tier 4 (CEMS monitoring), which tier is required if you receive HHV with some coal shipments, but not every coal shipment?

A84. If the unit is less than or equal to 250 mmBtu/hr, since you do not obtain HHV at the minimum frequency specified in §98.34(a), you may use Tier 1 to calculate CO2 mass emissions. However, if the unit is greater than 250 mmBtu/hr, then you must ensure that the carbon content of each shipment is determined and use Tier 3. (See §98.34(b)(3)(ii)(B)).

Unknown macro: {show-to}
Unknown macro: {center}

Footer / References Bar which is Visible to the public

Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration : none

Relevant Subparts: Subpart C

Unknown macro: {center}

History Panel For Internal Use - Not Visible to the Public

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)