Q68. 40 CFR §98.33(a)(3)(iii) indicates that “For units that combust municipal solid waste (MSW) and that produce steam, use Equation C-2c of this section”. However, Table C-1...

 

The footnote is intended to reinforce that Tier 1 cannot be used for units that combust MSW and generate steam. For units that combust MSW and generate steam, Tier 2 and the respective default values from Table C-1 may be used for a unit of any size if the use of Tier 4 is not required.

 

Updated on

Unknown macro: {show-to} Footer / References Bar which is Visible to the public
Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration: None

Relevant Subparts: Subpart C