Q338. For Tier 3, if I have multiple combustion sources using a single fuel type, should I enter this as an aggregation of units?

A338. While it is possible for an aggregation of units to use Tier 3 for certain fuel types, it is important to remember that the aggregation of units option is only allowed if each unit in the group is smaller than 250 mmBtu/hr. If the use of Tier 3 is required because any given unit is larger than 250 mmBtu/hr, the use of the aggregation of units option would not be allowed.

Unknown macro: {show-to}
Unknown macro: {center}

Footer / References Bar which is Visible to the public

Unknown macro: {show-to}

Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration : none

Relevant Subparts: Subpart C

Unknown macro: {center}

History Panel For Internal Use - Not Visible to the Public

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)