Q524. For a liquefied natural gas import facility, do boil-off venting emissions from an LNG storage tank need to be reported?
A524. Section 98.232(h) does not include boil-off venting from LNG storage tanks as an emission source under LNG import and export equipment; therefore, boil-off venting emissions from LNG storage tanks are not required. However, if the LNG storage tank is blown down to the atmosphere then reporting is required under 98.233(i).
Footer / References Bar which is Visible to the public
Updated on
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, http://www.epa.gov/climatechange/emissions/downloads11/documents/Subpart-W-additional-faq.pdf.
Approval / Publishing History: Version 2, Revised and Published by M Eaddy 4/23/2012
Expiration : none
Relevant Subpart: W
History Panel For Internal Use - Not Visible to the Public