Q87. What Tier, if any, must be used for a fuel not listed in Table C-1 that is less than 10% of the heat input of a combustion unit?
Note: The Cal e-GGRT help system includes general instruction on using the California GHG reporting tool. However, the help system may not explain differences between California and U.S. EPA reporting requirements. Please refer to the ARB reporting website for California-specific reporting requirements and additional help.

If the unit is less than or equal to 250 mmBtu/hr, GHG emissions reporting is not required if the fuel or the fuel constituents are not listed in Table C-1. However, if the unit is greater than 250 mmBtu/hr, CO2 emissions reporting for a fuel not listed in Table C-1 is required, using Tier 3, if: (1) combustion of the fuel accounts for 10% or more of the combustion unit’s annual heat input; and (2) the unit is not required to use Tier 4. This response applies only to units that calculate CO2 emissions in accordance with Subpart C.