Q82. For a non-Acid Rain combustion turbine rated over 250 mmBtu per hour that only burns diesel oil and pipeline natural gas, is it acceptable to use Tier 2...
Note: The Cal e-GGRT help system includes general instruction on using the California GHG reporting tool. However, the help system may not explain differences between California and U.S. EPA reporting requirements. Please refer to the ARB reporting website for California-specific reporting requirements and additional help.

Q82. For a non-Acid Rain combustion turbine rated over 250 mmBtu per hour that only burns diesel oil and pipeline natural gas, is it acceptable to use Tier 2 to calculate CO2 emissions? Is the use of Tier 2 also allowed if the turbine combusts only one of these fuels?

Yes, to both questions. Tier 2 may be used in a unit with a maximum rated heat input capacity greater than 250 mmBtu/hr for the combustion of pipeline natural gas and/or distillate fuel oil. (See §98.33(b)(2)(ii) and the definition of “distillate fuel oil” in §98.6.)

This web site is maintained by a contractor to the California Air Resources Board (RY2015.R.03)