Q86. Does Tier 3 have to be used if a unit is less than or equal to 250 mmBtu per hour, but has a continuous gas chromatograph to determine carbon content?

 

A86. Tier 3 is not required for any unit that is less than or equal to 250 mmBtu/hr, except as otherwise specified by another part of this subpart.  However a source may opt to use Tier 3 if it has the capability of determining carbon content and (if applicable) molecular weight at the required frequency specified in §98.34(b)(3). (See §98.33(b)(3).) 


Show If
special@authenticated
Footer / References Bar which is Visible to the public
Panel

Updated on

Page info
infoTypemodified-Modified date
typemodified-dateFlat
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}

...

Show If
special@authenticated
Info

Source: This question and answer was derived from a Legacy FAQ, revised by M. Hannan,

...

1/23/2013

...

.

Approval

...

/

...

Publishing

...

History:

...

Version 2,

...

approved

...

by

...

L.

...

Grogan-McCulloch,

...

2/13/2013

...

.

Expiration :

...

None

Relevant Subparts:

...

 Subpart C


History Panel For Internal Use - Not Visible to the Public