Q521. For a facility with equipment classified under 40 CFR 98.232(h)(4), is the correct methodology to conduct a leak detection survey as in 98.233(q) and use 98.233(r) to estimate emissions from sources determined to be leaking?

 

A520. For equipment in 98.232(h), other than vapor recovery compressors, the reporter should use methods in 98.233(q). For vapor recovery compressors the reporter should use methods in 98.233(r).

 

Wiki Markup
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}

Panel

Updated on

Page info
modified-date
modified-date
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, [http://www.epa.gov/ghgreporting/documents/pdf/2011/documents/Subpart-W-additional-faq.pdf].