The text below describes how to enter subpart C General Stationary Fuel Combustion Sources configuration-level emissions information. The process to edit an existing configuration type is essentially similar.
Wiki Markup |
---|
{composition-setup}{composition-setup} |
Click image to expand Wiki Markup |
---|
{cloak:id=PNG1|cloak.toggle.type=none| |
Cloak |
---|
cloak.toggle.zone=true} | true
Panel |
---|
Image Added |
Wiki Markup |
---|
{cloak} |
id | PNG1 |
---|
cloak.toggle.type | none |
Starting on the Subpart C Overview page, find the configuration type for which you would like to enter emissions information in the CONFIGURATION SUMMARY table and click OPEN.
Click image to expand Wiki Markup |
---|
Cloak |
---|
{cloak:id=PNG2|cloak.toggle.type=none|cloak.toggle.zone=true} | true
Panel |
---|
Image Added |
Wiki Markup |
---|
{cloak} |
id | PNG2 |
---|
cloak.toggle.type | none |
To edit a specific configuration, click the "Edit “Edit this Configuration Information" link above the CONFIGURATION-LEVEL EMISSIONS INFORMATION table.
Click image to expand Wiki Markup |
---|
Cloak |
---|
{cloak:id=PNG3|cloak.toggle.type=none|cloak.toggle.zone=true} | true
Panel |
---|
Image Added |
Wiki Markup |
---|
{cloak} |
id | PNG3 |
---|
cloak.toggle.type | none |
Use the text boxes and drop-down menus to update the entered information.
When finished, click SAVE.
Click image to expand Wiki Markup |
---|
{cloak:id=PNG4|cloak.toggle.type=none| |
Cloak |
---|
cloak.toggle.zone=true} | true
Panel |
---|
Image Added |
Wiki Markup |
---|
{cloak} |
id | PNG4 |
---|
cloak.toggle.type | none |
To enter emissions information for this configuration, find the CONFIGURATION EMISSIONS INFORMATION table and click EMISSIONS.
...
Excerpt |
---|
Note: Configuration Type 1 pictured. Click image to expand Wiki Markup |
---|
{cloak:id=PNG5|cloak.toggle.type=none| | Cloak |
---|
cloak.toggle.zone=true} | true
Panel |
---|
id | PNG5 |
---|
cloak.toggle.type | none |
---|
Image Added |
For configurations of Type 1 (single unit using Tiers 1, 2, or 3), subpart C requires the following additional information aggregated at the configuration-level: Wiki Markup | The total annual biogenic CO{~}2~ 2 mass emissions. This includes both CO{~}2~ 2 emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(b)(8)(ii)]unmigrated-wiki-markup- The total annual CO{~}2~ 2 mass emissions from sorbent \ [98.36(b)(10)]
For configurations of Type 3 (aggregation of units), subpart C requires the following additional information aggregated at the configuration-level: unmigrated-wiki-markup- The total annual biogenic CO{~}2~ 2 mass emissions. This includes both CO{~}2~ 2 emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(c)(1)(vi)]unmigrated-wiki-markup
- The total annual CO{~}2~ 2 mass emissions from the combustion of fossil fuels. This includes both CO{~}2~ 2 emissions from all fossil fuels and the fossil portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(c)(1)(vi)]
Wiki Markup | The total annual CO{~}2~ 2 mass emissions from sorbent \ [98.36(c)(1)\(x)]
For configurations of Type 4 (non-CEMS group of units sharing common fuel supply pipe), subpart C requires the following additional information aggregated at the configuration-level: unmigrated-wiki-markup- The total annual biogenic CO{~}2~ 2 mass emissions. This includes both CO{~}2~ 2 emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(c)(3)(vi)]
Wiki Markup |
---|
- The total annual CO{~}2~ 2 mass emissions from the combustion of fossil fuels. This includes both CO{~}2~ 2 emissions from all fossil fuels and the fossil portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(c)(3)(vi)]
Use the text boxes to enter the required information for your configuration type. When finished, click SAVE. Click image to expand Wiki Markup |
---|
Cloak |
---|
{cloak:id=PNG6|cloak.toggle.type=none|cloak.toggle.zone=true} | true
Panel |
---|
Image Added |
Wiki Markup |
---|
{cloak} | id | PNG6 |
---|
cloak.toggle.type | none |
For configurations of Type 2 (single unit using Tier 4) and Type 5 (monitored common stack or duct configurations), subpart C requires the following additional information aggregated at the configuration-level: unmigrated-wiki-markup- The cumulative CO{~}2~ 2 mass emissions for each quarter during the reporting year. The cumulative value is the sum of hourly emissions for the respective quarter only (for example, for the fourth quarter, the emissions will be summed for the fourth quarter only, not from all four quarters in the year). This value will include both biogenic and non-biogenic emissions \ [98.36(e)(2)(vi)(B)]
Wiki Markup | The total annual biogenic CO{~}2~ 2 mass emissions. This includes both CO{~}2~ 2 emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(b)(9)(ii), 98.36(c)(2)(viii)] Wiki Markup | The total annual non-biogenic CO{~}2~ 2 mass emissions (i.e. CO{~}2~ 2 mass emissions from fossil fuels, sorbent use, and process emissions) \ [98.36(b)(9)(ii), 98.36(c)(2)(viii)] Wiki Markup | The total annual CO{~}2~ 2 mass emissions measured by the CEMS. This will include both biogenic and non-biogenic emissions \ [98.36(b)(9)(1)-(ii), 98.36(c)(2)(viii)]unmigrated-wiki-markup- An indication (check box) if emissions reported for the CEMS include emissions calculated according to 98.33(a)(4)(viii) for a slipstream that bypassed the CEMS \ [98.33(a)(4)(viii)]
Wiki Markup | The total number of source operating hours in the reporting year \ [98.36(e)(2)(vi)(A)]unmigrated-wiki-markup- The total operating hours in which a substitute data value was used in the emissions calculations for the CO{~}2~ 2 concentration parameter (if an O2 monitor is used to calculate CO{~}2~ 2 concentration, report missing data for the O2 monitor here) \ [98.36(e)(2)(vi)(C), 98.3(c)(8)]
Wiki Markup | The total operating hours in which a substitute data value was used in the emissions calculations for the stack gas flow rate parameter \ [98.36(e)(2)(vi)(C), 98.3(c)(8)]unmigrated-wiki-markup- The total operating hours in which a substitute data value was used in the emissions calculations for the stack gas moisture content parameter (if moisture correction is required and a continuous moisture monitor is used) \ [98.36(e)(2)(vi)(C), 98.3(c)(8)]
- An indication (check box) of whether biogenic CO2 mass emissions were estimated using the methodology described by Equations C-12, C-13, and C-14 (See section 98.33(e)(2))
If biogenic CO2 emissions were estimated using the methodology described by Equations C-12, C-13, and C-14, the following additional information is required by subpart C for configurations of Type 2: unmigrated-wiki-markup- The total annual volume of CO{~}2~ 2 emitted from the combustion of all fuels \ [98.36(e)(2)(ix)(A)\]unmigrated-wiki-markup
- The total annual volume of CO{~}2~ 2 emitted from the combustion of all fossil fuels \ [98.36(e)(2)(ix)(B)\]unmigrated-wiki-markup
- The total annual volume of CO{~}2~ 2 emitted from the combustion of all biomass fuels \ [98.36(e)(2)(ix)(C)\]
Wiki Markup | The total annual biogenic CO{~}2~ 2 mass emissions calculated using the procedures in 98.33(e)(2) \ [98.36(e)(2)(ix)(G)\]
Use the text boxes and check box to enter the required information for your configuration type. When finished, click SAVE. Click image to expand Wiki Markup |
---|
Cloak |
---|
{cloak:id=PNG7|cloak.toggle.type=none|cloak.toggle.zone=true} | true
Panel |
---|
id | PNG7 |
---|
cloak.toggle.type | none |
---|
Image Added |
For configurations of Type 6 (year-round Part 75 heat input reporters), subpart C requires the following additional information aggregated at the configuration-level: Wiki Markup | The total annual biogenic CO{~}2~ 2 mass emissions. This includes both CO{~}2~ 2 emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ 2 emissions from fuels with a mixed biogenic and fossil component \ [98.36(d)(2)(ii)(I), 98.36(d)(2)(iii)(I)] - Report zero for this value if the facility elects to use the option specified in 98.3(c)(12) for the 2010 reporting year (where the facility chooses not to separately report biogenic emissions from part 75 units)
Wiki Markup | The total annual CO{~}2~ 2 emissions at the monitored location, as calculated by the applicable part 75 methodology. Include both biogenic and non-biogenic CO{~}2~ 2 in this value. \ [98.36(d)(2)(ii)(F), 98.36(d)(2)(iii)(F)]- If CO2 calculation methodology used was CEMS, the following additional elements are required:
Wiki Markup | The total number of source operating hours in the reporting year that the CO{~}2~ 2 concentration parameter was missing (if an O2 monitor is used to calculate CO{~}2~ 2 concentration, report missing data for the O2 monitor here) \ [98.3(c)(8)] Wiki Markup | The total number of source operating hours in the reporting year that the stack gas flow rate parameter was missing \ [98.3(c)(8)]unmigrated-wiki-markup- The total number of source operating hours in the reporting year that the moisture content parameter was missing (if a continuous monitor is in use) \ [98.3(c)(8)]
- If CO2 calculation methodology used was the Appendix D and G calculation method, the following additional elements are required:
unmigrated-wiki-markup- Total number of operating hours during the year that fuel flow rate data was missing \ [98.3(c)(8)]unmigrated-wiki-markup
- Total number of operating hours during the year that high heating value data was missing \ [98.3(c)(8)]
|
Use the text boxes to enter the required information for your configuration type.
...