longname |
---|
Wiki Markup |
{longname} Q85. Is the use of Subpart C tiers required after 2010 and is it acceptable to use the best available monitoring provisions under Subpart A beyond 2010? {longname} |
A85.
...
Yes,
...
the
...
use
...
of
...
Subpart
...
C
...
Tiers
...
is
...
required
...
after
...
2010.
...
The
...
use
...
of
...
best
...
available
...
monitoring
...
methods
...
as
...
described
...
in
...
Subpart
...
A
...
may
...
not
...
be
...
extended
...
beyond
...
the
...
end
...
of
...
2010
...
except
...
for
...
units
...
subject
...
to
...
subpart
...
P
...
(Hydrogen
...
Production),
...
subpart
...
X
...
(Petrochemical
...
Production),
...
or
...
subpart
...
Y
...
(Petroleum
...
Refineries).
...
Note
...
that
...
there
...
may
...
be
...
subpart
...
specific
...
BAMM
...
requirements
...
not
...
included
...
in
...
subpart
...
A
...
-.
...
Note,
...
however,
...
that
...
this
...
timing
...
does
...
not
...
apply
...
to
...
subpart-specific
...
BAMM
...
requirements-.
...
(See
...
§98.3(d)(2)(iii)
...
and
...
§98.3(j).)
...
Wiki Markup |
---|
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to} |
Panel | |||
---|---|---|---|
} Updated onon
|
Wiki Markup |
---|
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ, revised by M. Hannan, 1/23/2013
Approval / Publishing History: Version 2, approved by L. Grogan-McCulloch, 2/13/2013
Expiration: none
Relevant Subparts: Subpart C
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to} |