Q581. Under §98.233(e)(1), emissions must be calculated from dehydrator vents with throughput greater than or equal to 0.4 million standard cubic feet per day. Is this throughput specific to vent throughput or dehydrator throughput?

 

A581. The annual average daily throughput of 0.4 million standard cubic feet per day refers to the dehydrator throughput of natural gas for §98.233(e).

 

Wiki Markup
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to}

Panel

Updated on

Page info
modified-date
modified-date
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: EPA, Frequently Asked Questions, Petroleum and Natural Gas Systems, July 2011, [http://www.epa.gov/ghgreporting/documents/pdf/2011/documents/Subpart-W-additional-faq.pdf]. Clarified

Approval / Publishing History: Version 1, Approved by M. Eaddy, 6/4/2012

Expiration : none

Relevant Subpart: W, Dehydrators
{info}{_}History Panel For Internal Use - Not Visible to the Public{_}{show-to}