Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.
Wiki Markup
{longname}
Q82. For a non-Acid Rain combustion turbine rated over 250 mmBtu per hour that only burns diesel oil and pipeline natural gas, is it acceptable to use Tier 2 to calculate CO2 emissions? Is the use of Tier 2 also allowed if the turbine combusts only one of these fuels?
{longname}

A82. Yes, to both questions. Tier 2 may be used in a unit with a maximum rated heat input capacity greater than 250 mmBtu/hr for the combustion of pipeline natural gas and/or distillate fuel oil. (See §98.33(b)(2)(ii) and the definition of "distillate fuel oil" in §98.6.)

{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}
{panel}Updated on {page-info:modified-date|dateformat=dd/MM/YY HH:mm}{panel}
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ

Approval / Publishing History: Version 1

Expiration : None

Relevant Subparts:  Subpart C
{info}{center}{_}History Panel For Internal Use - Not Visible to the Public{_}{center}{show-to}

This web site is maintained by a contractor to the U.S. Environmental Protection Agency (RY2021.R.02)