Q308. How do you report in e-GGRT a fuel that changed calculation methodology from Tier 1 to Tier 2 for a given configuration during the middle of the year?
A308. You must add the fuel twice for the configuration. Each addition of the fuel should specify a different calculation methodology and the calculation methodology periods should be discrete. You also must identify the change in calculation methodology in the subpart A reporting module. This approach is valid when switching between Tiers 1, 2, or 3. If switching from Tiers 1, 2, or 3 to Tier 4, a new configuration would have to be added for when the methodology was switched to Tier 4.
...
|
Footer / References Bar which is Visible to the public |
...
Panel |
---|
Updated on Page info |
---|
infoType | Modified modified- datemodified-date |
---|
type | Flat |
---|
dateformat | dd/MM/YY HH:mm |
---|
|
|
...
Show If |
---|
|
Info |
---|
Source: This question and answer was derived from a Legacy FAQ. Approval / Publishing History: Version 1 Expiration : None Relevant Subparts: Subpart C |