Q73. If a non-Acid Rain unit combusts coal or other solid fossil fuel and has gas monitors installed but does not have a stack flow monitor, is installation and certification of a stack flow monitor required?
A73. If the unit and the currently installed gas monitors meet all six conditions specified in §98.33(b)(4)(ii), then the Tier 4 methodology must be used, and a flow monitor must be installed and certified prior to the applicable deadline specified in §98.33(b)(5). (See §98.34(c).)
Show If |
---|
|
Footer / References Bar which is Visible to the public |
Panel |
---|
Updated on on Page info |
---|
| modified-date |
---|
| modified-date |
---|
dateformat | dd/MM/YY HH:mm |
---|
|
|
Wiki Markup |
---|
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to} |
...
Show If |
---|
|
Info |
---|
Source: This question and answer was derived from a Legacy FAQ, revised by D. Richards, |
|
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...
...