Q73. If a non-Acid Rain unit combusts coal or other solid fossil fuel and has gas monitors installed but does not have a stack flow monitor, is installation and certification of a stack flow monitor required?
A73. If the unit and the currently installed gas monitors meet all six conditions specified in §98.33(b)(4)(ii), then the Tier 4 methodology must be used, and a flow monitor must be installed and certified prior to the applicable deadline specified in §98.33(b)(5). (See §98.34(c).)
Panel | ||||||||
---|---|---|---|---|---|---|---|---|
Updated on
|
Wiki Markup |
---|
{show-to:group=confluence-Users}{_}Footer / References Bar which is Visible to the public{_}{show-to} |
Wiki Markup |
---|
{show-to:group=confluence-Users} {info} Source: This question and answer was derived from a Legacy FAQ, revised by D. Richards, 11/14/2011 Approval / Publishing History: Version 1, approved by M. Hannan, 1/23/2103 Expiration: none Relevant Subparts: Subpart C {info}{_}History Panel For Internal Use - Not Visible to the Public{_}{show-to} |