Q794.

...

If

...

I

...

have

...

multiple

...

anaerobic

...

lagoons,

...

do

...

I

...

need

...

to

...

report

...

for

...

each

...

one?

 

A794.  Subpart II, 98.352 requires a facility to report CH4 generation, CH4 emissions and CH4 recovered from treatment of industrial wastewater at each anaerobic process. For anaerobic reactors and lagoons, the rule states that facilities must calculate CH4 generation using the volume of wastewater sent to an anaerobic treatment process and average concentration of COD or BOD5 of wastewater entering an anaerobic treatment process with either equation II-1 or II-2. Equations II-1 and II-2 include the variable MCF, or methane conversion factor. Reporters must use MCF of 0.8 for anaerobic deep lagoons (depth more than 2 m) or MCF of 0.2 for anaerobic shallow lagoon (depth less than 2 m).

...

Wiki Markup
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to}
Panel

Updated on

Page info
modified-date
modified-date
dateformatdd/MM/YY HH:mm

Wiki Markup
{show-to:group=confluence-Users}
{info}
Source: Rachel Schmeltz, 2/24/2014 (Anaerobic Lagon FAQ_0202114v2.docx)