longname |
---|
Q85. Is the use of Subpart C tiers required after 2010 and is it acceptable to use the best available monitoring provisions under Subpart A beyond 2010?
|
A85. Yes, the use of Subpart C Tiers is required after 2010. The use of best available monitoring methods as described in Subpart A may not be extended beyond the end of 2010 except for units subject to subpart P (Hydrogen Production), subpart X (Petrochemical Production), or subpart Y (Petroleum Refineries). Note that there may be subpart specific BAMM requirements not included in subpart A-. Note, however, that this timing does not apply to subpart-specific BAMM requirements-. (See §98.3(d)(2)(iii) and §98.3(j).)
Wiki Markup |
---|
{show-to:group=confluence-Users}{center}{_}Footer / References Bar which is Visible to the public{_}{center}{show-to} |
Panel |
---|
Updated on Page info |
---|
| modified-date |
---|
| modified-date |
---|
dateformat | dd/MM/YY HH:mm |
---|
|
|
Wiki Markup |
---|
{show-to:group=confluence-Users}
{info}
Source: This question and answer was derived from a Legacy FAQ, revised by M. Hannan, 1/23/2013
Approval / Publishing History: Version 2, approved by L. Grogan-McCulloch, 2/13/2013
Expiration: none
Relevant Subparts: Subpart C