...
To delete an existing Sulfur Recovery Plant, click on the delete icon, which is the last column in the SULFUR RECOVERY UNIT-LEVEL EMISSIONS SUMMARY table.
Wiki Markup |
{ Composition Setup |
}{composition-setup} |
---|
|
Wiki Markup |
{
:=}Click image to expand ![](/confluence/download/attachments/112035260/overview9.png?version=2&modificationDate=1330015199000&api=v2)
Cloak |
---|
Wiki Markup |
---|
{cloak:id=PNG1|cloak.toggle.zone | true |
---|
id | PNG1 |
---|
| | =none|cloak.toggle.zone=true} |
|
Panel |
---|
![](/confluence/download/attachments/112035260/overview9.png?version=2&modificationDate=1330015199000&api=v2)
|
unmigrated-inline-wiki-markup{ |
Subpart Y collects the following data about your sulfur recovery plant:
...
When you are finished, click NEXT.
...
{ Composition Setup |
}{composition-setup}
...
{
:=}Click image to expand ![](/confluence/download/attachments/112035260/edit_sulfur_recovery_plant.png?version=4&modificationDate=1330015539000&api=v2)
Cloak |
---|
Wiki Markup |
---|
{cloak:id=PNG2|cloak.toggle.zone | true |
---|
id | PNG2 |
---|
| | =none|cloak.toggle.zone=true} |
|
Panel |
---|
![](/confluence/download/attachments/112035260/edit_sulfur_recovery_plant.png?version=4&modificationDate=1330015539000&api=v2)
|
Excerpt |
---|
Subpart Y collects the following data about your sulfur recovery plant: - Maximum rated throughput of the sulfur recovery plant (metric tons sulfur per stream day)
- Type of sulfur recovery plant:
- Caustic scrubber
- Claus
- Lo-cat
- Sulfuric acid plant
- Other (specify)
- Method used to calculate the CO2 emissions. Specify either Equation Y-12 or Process Vent Method. [Only appears if No is selected for using a CEMS. For Claus Plants (that do not use a CEMS according to Subpart C), Equation Y-12 must be used. For non-Claus plants (that do not use a CEMS according to Subpart C), either Equation Y-12 or the Process Vent Method may be used.]
- Indicate whether, if you recycle tail gas, the recycled flow rate and carbon content of recycled tail gas is included in the measured volumetric flow and carbon mole fraction data. If you do not recycle tail gas, please select No. [This question appears only if Equation Y-12 is selected]. Click either Yes or No.
- Indicate if a correction for CO2 emissions in the tail gas is used. [This question appears only if Yes is selected for previous question]. Click either Yes or No. Note that per Section 98.253(f)(5), if tail gas is recycled to the front of the sulfur recovery plant and the recycled flow rate and carbon content is included in the measured data, then the annual CO2 emissions must be corrected to avoid double counting these emissions.
|
When you are finished, click SAVE.
...
To add or update emissions information for a sulfur recovery plant that is NOT monitored by CEMS, locate the SULFUR RECOVERY UNITS EMISSIONS SUMMARY table on the Subpart Y Overview page, and click OPEN.
...
{composition-setup}{ Composition Setup |
} |
---|
|
Wiki Markup |
{
:=}Click image to expand ![](/confluence/download/attachments/112035260/overview12.png?version=4&modificationDate=1330015536000&api=v2)
Cloak |
---|
Wiki Markup |
---|
{cloak:id=PNG3|cloak.toggle.zone | true |
---|
id | PNG3 |
---|
| | =none|cloak.toggle.zone=true} |
|
Panel |
---|
![](/confluence/download/attachments/112035260/overview12.png?version=4&modificationDate=1330015536000&api=v2)
|
Depending on the methods selected to calculate CO2 emissions (see previous section titled “Adding or Updating Sulfur Recovery Plant Information”), you will be presented with screens to collect CO2 emission results and additional data. Each specific screen is discussed below.
...
When you have finished entering emission results, click SAVE.
Wiki Markup |
{ Composition Setup |
}{composition-setup}
...
{
:=}Click image to expand ![](/confluence/download/attachments/112035260/sulfur_recovery_plant_Y-12.png?version=4&modificationDate=1330015537000&api=v2)
Cloak |
---|
Wiki Markup |
---|
{cloak:id=PNG4|cloak.toggle.zone | true |
---|
id | PNG4 |
---|
| | =none|cloak.toggle.zone=true} |
|
Panel |
---|
![](/confluence/download/attachments/112035260/sulfur_recovery_plant_Y-12.png?version=4&modificationDate=1330015537000&api=v2)
|
unmigrated-inline-wiki-markup{ |
Process Vent Method (Equation Y-19) Summary and Result
...
When you have finished entering emission results, click SAVE.
...
{ Composition Setup |
}{composition-setup}
...
{
:=}Click image to expand ![](/confluence/download/attachments/112035260/process_vent_method.png?version=4&modificationDate=1330015536000&api=v2)
Cloak |
---|
Wiki Markup |
---|
{cloak:id=PNG5|cloak.toggle.zone | true |
---|
id | PNG5 |
---|
| | =none|cloak.toggle.zone=true} |
|
Panel |
---|
![](/confluence/download/attachments/112035260/process_vent_method.png?version=4&modificationDate=1330015536000&api=v2)
|
#Back to Top
See Also
Screen Errors
Using Cal e-GGRT to Prepare Your Subpart Y Report
Subpart Y Summary Information for this Facility
Subpart Y Delayed Coking Unit Information
Subpart Y Asphalt Blowing Unit Information
Subpart Y Coke Calcining Unit Information
Subpart Y Catalytic Cracking, Fluid Coking, and Catalytic Reforming Unit Information
Subpart Y Flares Unit Information
Subpart Y Process Vents Unit Information
Subpart Y Sulfur Recovery Plant Information
Subpart Y Emissions Information for Process Units Monitored by CEMS
Subpart Validation Report