Subpart D Unit Emissions Information
Note: The Cal e-GGRT help system includes general instruction on using the California GHG reporting tool. However, the help system may not explain differences between California and U.S. EPA reporting requirements. Please refer to the ARB reporting website for California-specific reporting requirements and additional help.

Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

Anchor
Back to Top
Back to Top

The text below describes how to enter subpart D Electricity Generation emissions information for each unit at your facility. The process to edit an existing unit is essentially similar.

Adding or Updating Unit Emissions Information

Composition Setup

Toggle Cloak
idPNG1
Click image to expand

Cloak
cloak.toggle.zonetrue
idPNG1
cloak.toggle.typenone

Starting on the Subpart D Overview page, find the unit for which you would like to enter emissions information in the SOURCE SUMMARY table and click OPEN.

Toggle Cloak
idPNG2
Click image to expand

Cloak
cloak.toggle.zonetrue
idPNG2
cloak.toggle.typenone

To edit the configuration information for this unit or group, click the "Edit the Information for this Unit/Stack/Pipe" link above the UNIT/STACK/PIPE EMISSIONS INFORMATION table.

Toggle Cloak
idPNG3
Click image to expand

Cloak
cloak.toggle.zonetrue
idPNG3
cloak.toggle.typenone

Use the text boxes, drop-down menu, and radio buttons to update the entered information.

When finished, click SAVE.

Toggle Cloak
idPNG4
Click image to expand

Cloak
cloak.toggle.zonetrue
idPNG4
cloak.toggle.typenone

To enter emissions information for this configuration, find the UNIT/STACK/PIPE EMISSIONS INFORMATION table and click OPEN.

The unit emissions data entry screen will vary slightly depending on the Part 75 methodology selected for each unit.

Toggle Cloak
idPNG5
Click image to expand

Cloak
cloak.toggle.zonetrue
idPNG5
cloak.toggle.typenone

Excerpt

For each unit, subpart D requires the facility to provide the following aggregated fuel emissions data:

  • Wiki Markup
    The total annual CO{~}2~ emissions, including biomass, at the monitored location in short tons (as reported under part 75) \[98.36(d)(1)(ii)\]
  • Wiki Markup
    The total annual CO{~}2~ emissions, for fossil fuels only, at the monitored location in metric tons (conversion from the short ton value reported under part 75) \[98.36(d)(1)(ii)\]
  • Wiki Markup
    The total annual biogenic CO{~}2~ emissions. This includes both CO{~}2~ emissions from the combustion of biomass fuels and the biogenic portion of CO{~}2~ emissions from fuels with a mixed biogenic and fossil component \[98.36(d)(1)(ix)\]
    • Report zero for this value if the facility elects to use the option specified in 98.3(c)(12) for the 2010 reporting year (where the facility chooses not to separately report biogenic emissions from part 75 units)

Wiki Markup
For each unit for which the facility selects "*CEMS*" as the Part 75 methodology used to determine CO{~}2~ mass emissions, subpart D requires the facility to provide the following additional information \[98.3(c)(8)\]:

  • The total number of operating hours during the year that CO2 concentration was missing
  • The total number of operating hours during the year that stack gas flow rate was missing
  • The total number of operating hours during the year that moisture content was missing (only if a continuous moisture monitor was in use)

Wiki Markup
For each unit for which the facility selects "*Appendix G, Equation G-4*" as the Part 75 methodology used to determine CO{~}2~ mass emissions, subpart D requires the facility to provide the following additional information \[98.3(c)(8)\]:

  • The total number of operating hours during the year that fuel flow rate was missing
  • The total number of operating hours during the year that high heating value was missing

Wiki Markup
For each unit for which the facility selects "*Appendix G, Equation G-1*" as the Part 75 methodology used to determine CO{~}2~ mass emissions, subpart D requires the facility to provide the following additional information \[98.3(c)(8)\]:

  • The total number of operating hours during the year that fuel carbon content was missing

For each unit for which the facility selects "LME calculation methods in 40 CFR 75 19" as the Part 75 methodology used to determine CO2 mass emissions, provide the following additional information:

  • The total number of operating hours during the year that fuel flow rate was missing
  • The total number of operating hours during the reporting year that oil density was missing
  • The total number of operating hours during the reporting year that high heating value was missing

Use the text boxes to enter the required information.

When finished, click SAVE.

Once you have entered the required unit emissions information for all units and groups at your facility, you will have finished entering the required unit emissions information for your facility.

#Back to Top

See Also

Screen Errors
Using e-GGRT to Prepare Your Subpart D Report
Subpart D Unit Information
Subpart D Fuel Information
Subpart D Fuel Emissions Information
Subpart Validation Report